EasyManua.ls Logo

Oriental motor BLH Series - Connecting the RS-485 Communication Cable (CN5, CN6)

Oriental motor BLH Series
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
Connection
6.8 Connecting the RS-485 communication cable (CN5, CN6)
Connect this cable when controlling the driver via RS-485
communication.
Connect the RS-485 communication cable to the CN5
connector or the CN6 connector on the driver. The vacant
connector can be used to connect a dierent driver.
RS-485 communication cables for connection (sold
separately) are available.
z
Model
Cable for connecting between driver and controlle 3 m (9.8 ft.):
CC030-RS
Cable for connecting between drivers 150 mm (5.91 in.):
LH0015-RWN
Pin assignments
Pin No. Signal name Description
CC030-RS
wire color
3
2
1
1 TR+ RS-485 communication signal (+) White
2 TR− RS-485 communication signal (−) Gray
3 GND GND Orange
Housing: PAP-03V-S (JST)
Terminal: SPHD-001T-P0.5 (JST)
SPHD-002T-P0.5 (JST)
Applicable lead wire
SPHD-001T-P0.5 AWG26 to 22 (0.13 to 0.33 mm
2
)
SPHD-002T-P0.5 AWG28 to 24 (0.08 to 0.21 mm
2
)
Internal input circuit
3 GND
2 TR
-
1 TR+
3 GND
2 TR
-
1 TR+
0 V
120
1 k
1 k
5 V
0 V
TERM. TERM.
Note
Keep 10 m (32.8 ft.) or less for the total extension distance of the RS-485 communication cable.
Use a twisted-pair cable when using a communication cable other than the
CC030-RS
.
Keep 15 units or less for the number of drivers connected.