132
How to use MEXE02
4. Execute teaching/remote operation using buttons in the window.
1 Selects the operation data number that the teaching function is performed.
2 This button is used to rotate the motor in the reverse direction.
3 This button is used to rotate the motor in the forward direction.
4 This button is used to decelerate the motor to a stop.
5 This button is used to accelerate the motor rotation speed.
6 This button is used to decelerate the motor rotation speed.
7 Sets the changing value in the rotation speed when pressing 5 or 6 once.
8 This is the operation data to be changed with the teaching function. The value can be changed directly.
9 This is the operation data presently written in the driver.
10
*
Writes the teaching data to the operation data number selected by
①
.
11 This button is used instantaneously to stop the motor that is rotating by pressing 2 or 3.
*
When the teaching data is written to the operation data number, execute while the motor is in a standstill state.
5. To exit the teaching/remote operation, unselect "Start the teaching/remote operation."
If "Start the teaching/remote operation" is unselected while the motor rotates, the following window appears.
Clicking "Yes" causes the motor to stop instantaneously.
Note
•
If the communication is disconnected while the motor rotates, the motor stops instantaneously.
•
If the operation input signal was ON (active state) when teaching/remote operation is completed, the operation
prohibited information is generated. The operation prohibited information can be cleared by turning the operation
input signal OFF.