21
Operation data
Using an external potentiometer
An external potentiometer is used to set the speed.
Use the
PAVR2-20K
(sold separately) for an external potentiometer.
Setting range: 0, 80 to 3150 r/min
LOW
HIGH
PAVR2-20K
(sold separately)
21
3
VH
VM
VL
I/O signal connecto
(CN2)
0 to 20 kΩ
Blue
Green
Yellow
6
5
4
Rotation speed (r/min)
PAVR2-20K (scale)
External potentiometer -
Rotation speed characteristics
(representative values)
LOW
500
1000
1500
2000
2500
3000
Using external DC voltage
External DC voltage is used when the speed is set from an external control device.
For the external DC voltage, use a DC power supply (0 to 5 VDC, 1 mA or more) with reinforced insulation on its primary
and secondary sides.
Setting range: 0, 80 to 3150 r/min
0 to 5 VDC
1 mA or more
VM
VL
Green
Yellow
(CN2)
5
4
+
–
Rotation speed characteristics
(representative values)
Rotation speed (r/min)
012345
Setting voltage (VDC)
500
1000
1500
2000
2500
3000
Using PWM signal input
The rotation speed is set by inputting the PWM signal.
The rotation speed varies according to the duty cycle of input PWM signals.
Setting range: 0, 80 to 3150 r/min
VM
VL
PWM signal
Green
Yellow
(CN2)
5
4
+
–
Rotation speed characteristics
(representative values)
Rotation speed (r/min)
100
0
500
1000
1500
2000
2500
3000
V
H
V
L
T
H
T
PWM duty cycle (%) = ×100
T
H
T
PWM frequency
∗
(kHz) =
1
T
V
H
= 4.5 to 5.0 V V
L
= 0 to 0.5
Available for 1 kHz to 25 kHz
•
Input signal specications