125
How to use MEXE02
Status monitor
The present status of the driver can be monitored.
1. Start the "Status monitor."
2. Click "Start Status monitor."
Status monitor starts.
3. To exit the status monitor, unselect "Start Status monitor."
z
How to view the status monitor window
Main monitored items Description
Command speed (motor shaft) Monitors the present command speed.
Actual speed (motor shaft) Monitors the present feedback speed.
Command speed (gearhead shaft) Monitors the present command speed as a value converted by the set speed reduction ratio.
Actual speed (gearhead shaft) Monitors the present feedback speed as a value converted by the set speed reduction ratio.
Inverter voltage Monitors the present voltage value inside the driver.
Load factor
Monitors the present motor output torque as a load factor. The load factor is a value based on the
rated torque being 100%.
Elapsed time from BOOT Monitors the time that has elapsed since the power supply was turned on.
Driver temperature Monitors the present driver temperature.
Odometer Monitors the cumulative rotation amount inside the driver since the driver was started operating.
Tripmeter
Monitors the total rotation amount inside the driver. The value of the tripmeter can be cleared by
executing "Clear tripmeter."
Rotation amount meter
Monitors the rotation amount inside the driver. The value of the rotation amount meter can be
cleared by executing "Clear rotation amount meter" or turning on the power again.
Selection number Monitors the operation data number presently selected.
Operation data setting method Monitors the setting method of each operation data presently selected.
Operation data setting value Monitors the setting value of each operation data presently selected.
External analog setting device
(input voltage)
*
Monitors the voltage value of the external analog setting device presently input.
PWM signal input (duty cycle)
*
Monitors the duty cycle of the PWM signal presently input.
LED output Monitors the output status of the LED.
Alarm
Monitors the present alarm status. Details of the alarm generated and the driver status when the
alarm was generated can be checked using the alarm monitor.
Information
Monitors the present information status. Details of the information can be checked using the
information monitor.
Communication error
Monitors the present communication error status. Details of the communication error can be
checked using the RS-485 communication monitor.
Sequence information
Monitors the operation data numbers executed previously (the latest 16 data). "−" is displayed
when the motor is stopped, and the value same as the selection number is displayed during
operation. The sequence information can be cleared by executing "Clear sequence history."
*
"−" is displayed if not selected in the "External setting method" parameter.