How to use MEXE02
Items that can be checked in the alarm history
Item Description
Code (Hex) This is a code to represent the content of the generated alarm.
Alarm message This is the content of the generated alarm.
Driver temperature This is the driver temperature when an alarm was generated.
Inverter voltage This is the internal voltage of the driver when an alarm was generated.
Selection Number This is the operation data number selected when an alarm was generated.
Load factor This is the load factor when an alarm was generated.
Command Speed This is the command speed when an alarm was generated.
Feedback speed This is the feedback speed when an alarm was generated.
Elapsed time from BOOT This is the elapsed time until an alarm was generated from when the power was turned on.
Elapsed time from Motor
move
This is the elapsed time until an alarm was generated from the start of operation.
Main power supply time
This is the cumulative elapsed time until an alarm was generated from when the main power supply
was rst time turned on.
Direct input
*
This is the input status of the direct inputs (D-IN0 to D-IN4) when an alarm was generated. It is
indicated in hexadecimal.
Remote input
*
This is the input status of the remote inputs (R-IN0 to R-IN15) when an alarm was generated. It is
indicated in hexadecimal.
Internal I/O
*
This is the internal status of I/O signals when an alarm was generated. It is indicated in hexadecimal.
Sub code
*
This is our code for checking.
*
Details of each bit can be checked at the bottom of the alarm monitor window. (ON: green, OFF: white)
When the sensor error at power-on and the EEPROM error shortly after power-on are generated, "0" is shown in all
elds. (Except for code, alarm message, main power supply time, internal I/O, and sub code)
3. To exit the alarm monitor, unselect "Start the alarm monitor."
Note
Clearing the alarm history cannot be executed in a state where the HMI input is OFF (non-active state).
Information monitor
Information generation status and information history of the driver can be checked.
1. Start the "Information monitor."
2. Click "Start information monitor."
The information monitor starts.
Indication Information status
ON (green) Generated
OFF (white) Not generated
3. To exit the information monitor, unselect "Start the Information monitor."
Note
•
Information history is saved in the RAM, so they are cleared when the power supply of the driver is turned o.
•
Clearing the information history cannot be executed in a state where the HMI input is OFF (non-active state).