EasyManua.ls Logo

Oriental motor BLH Series - Page 18

Oriental motor BLH Series
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Connection
Notes about installation and wiring
Connect the motor, driver and other peripheral control equipment directly to the grounding point so as to prevent a
potential dierence from developing between grounds.
When relays or electromagnetic switches are used together with the system, use noise lters and CR circuits to
suppress surges generated by them.
Keep a power supply cable and a signal cable as short as possible without coiling and bundling extra lengths.
Separate power lines such as the motor cable and the power supply cable from signal lines, and wire them apart as
much as possible [example: about 100 to 200 mm (3.94 to 7.87 in.)]. If the power lines must cross over the signal lines,
wire them at right angles.
Example of installation and wiring
RS-485 communication cable
Host controller
Motor
Driver
I/O signal cable
[3 m (9.8 ft.) or less]
External potentiometer cable
[3 m (9.8 ft.) or less]
DC power supply
(Grounded panel)
Motor
cable
External
potentiometer
Grounding
Grounding
Grounding
Grounding
Power supply cable
[2 m (6.6 ft.) or less]
*
Shielded cable
Precautions about static electricity
Static electricity may cause the driver to malfunction or suer damage. Be careful of handling the driver while the power
is supplied.
Note
Do not approach or touch the driver while the power is supplied.
Always use an insulated screwdriver to set the address number setting switch and the termination resistor switch of
the driver.