I/O signals
VA output
When the feedback speed reached the "plus or minus range of VA detection width with respect to the setting speed,"
this output is turned ON.
A range to turn the VA output ON can be set using the "VA detection width" parameter.
Related parameters
Parameter name Description Setting range Factory setting
VA detection width Sets the detection width for the VA output. 1 to 400 r/min] 200
Example: When the motor speed changes from the setting speed 1 to the setting speed 2
“ VA detection width ”
Setting speed 1
Setting speed 2
Motor speed
ON
OFF
VA output
ON
“ VA detection width
“ VA detection width
Information bit output
If corresponding information is generated, each output signal is turned ON.
Information
Information bit output
signal
Information
Information bit output
signal
Driver temperature INFO-DRVTMP Odometer INFO-ODO
Overvoltage INFO-OVOLT Torque limiting value setting error INFO-TRQ-DE
Undervoltage INFO-UVOLT Rotation speed setting error INFO-SPD-DE
Load INFO-LOAD Main power supply time INFO-PTIME
Speed INFO-SPD Main power supply count INFO-PCOUNT
Operation data setting error INFO-SET-E Operation start limit mode INFO-DSLMTD
Operation prohibited INFO-DRV I/O test mode INFO-IOTEST
RS-485 communication error INFO-NET-E Conguration request INFO-CFG
Rotation amount meter INFO-REV Power cycling request INFO-RBT
Tripmeter INFO-TRIP
SYS-BSY output
This signal is turned ON in the following conditions.
•
When the maintenance command is executed via RS-485 communication
•
When Conguration, teaching/remote operation, or I/O test is being executed with the
MEXE02
•
When writing of operation data or parameters is being executed with the
MEXE02
Rewriting of the operation data or executing the maintenance command are not allowed in a state where the SYS-BSY
output is being ON.
MPS output
The MPS output is turned ON when the main power supply is turned on.