PROGram[:SELected]:CHANges? <nr1>, <cr>
This command compares the program that is executing with another
program stored in the memory type and location passed as
parameters. The results of the comparison is returned as a decimal
number ranging from 0 to 15 representing a four bit binary value.
This result can be decoded as shown below.
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Bit 0: If set to 1, there are differences in the steady state table (SST)
Bit 1: If set to 1, there are differences in the transient table (TT)
Bit 2: If set to 1, there are differences in the ALIAS of the program
Bit 3: If set to 1, there are differences in INFOrmation of the program
If the query returns zero (0), the program executing is identical to the
stored program referenced.
If the command returns three (3), the program executing has
differences with the referenced program in both the steady state
table and the transient table.
PROGram[:SELected]:COPY <nr1> [,<cr>]
This command copies the selected program as previously specified by
the PROG:NAME <nr1> command to destination program number.
NOTE: The destination Program specified cannot be currently
DESTINATION PROGRAM NUMBER <nr1>
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
PROGram:EXECuted:COPY <nr1> [,<cr>]
This command copies the executed program to destination program
number.
DESTINATION PROGRAM NUMBER <nr1>
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB