ADF SERIES™ OPERATION MANUAL
SECTION 8:
Remote Control Programming
Entire Contents Copyright 2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
ADF Series Power Source Operation Manual Page 191 of 349
8.6.2 Execution Commands
The following commands may be used to control stored program executions.
PROGram[:SELected]:EXECute [<nr1> [,<cr>]
This command executes the selected program (default) or the
program number passed as the first parameter.
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
PROGram[:SELected]:EXECute ?
The query format returns the number of the program that is in effect.