EasyManua.ls Logo

Panasonic KX-TDA30

Panasonic KX-TDA30
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.7 Connection of DECT Portable Stations — KX-TDA30
Installation Manual 323
• The CS should not be placed outdoors (use indoors).
• The CS should not be placed near high voltage equipment.
• The CS should not be placed on a metal object.
• Do not use this wireless system near another high power cordless system such as
DECT or SS wireless.
• Keep the distances listed below between equipment in order to prevent noise,
interference or the disconnection of a conversation. (The distance may vary
depending on the environment.)
Equipment Distance
CS and office equipment such as a computer, telex,
fax machine, etc., or microwaves
More than 2 m
CS and PS More than 1 m
Each PS More than 0.5 m
Hybrid IP-PBX and CS More than 2 m
Too many CSs in a small area can cause problems due to conflicts over which signal
channels each CS can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.

Table of Contents

Other manuals for Panasonic KX-TDA30

Related product manuals