ENGLISH
11.6 Analog Input Modules (SCMI-600-01)
Designation Properties Description
Number 4
Plug 3× 5-pin, ODU
1× 5-pin, M12×1
Inputs INx-1, INx-2, INx-3, INx-4, INx-5
Voltage +24 V
DC
Per network
Power supply max. 250 mA Thermal fuse
Interface Measuring bus based on RS-422
Housing material ABS/PC
Housing sealing TPE
Type of protection IP65 When installed
Ambient temperature -10 – +50°C
Storage temperature -20 – +60°C
11.6.1 Connections, SC Sensors
Designation Properties Description
Number 3
Plug 5-pin, ODU For Parker sensors
Inputs INx-1, INx-2, INx-3 Analog
Voltage +12 V
DC
Power supply max. 70 mA Thermal fuse
Fuse Protection against overvoltage,
short-circuit protected
Active current monitoring for
each channel
Accuracy 0.1 % FS (full scale) = end value of measuring
range
Input signal range -3.4 V – +3.4 V
Scanning rate 1 ms = 1,000 measured values/s
11.6.2 Connection, External Sensor
Designation Properties Description
Number 1
Plug 5-pin, M12×1 For sensors with current/volt-
age output
Inputs INx-4, INx-5 Analog
Voltage +24 V
DC
Per network
Power supply Max. 100mA Thermal fuse
Accuracy 0.1 % FS (full scale) = end value of measuring range
Input signal range -3.4 V – +3.4 V
Scanning rate 1 ms = 1,000 measured value/s
(FAST MODE at 100µs)
268
The Parker Service Master CONNECT V1.0/04/20
Technical Data