21
1
3
2
"- LEVEL EXPERT- PELLENC POWER TOOL BATTERY" Workshop document
Issue 11/2016 ref. : DOCUMENT ATELIER_BATTERIE_EXP_OUTILS_PELLENC_V2_2016_ENG
To do the charging voltage test with the 50V<V>50.4V test lead, connect the multimeter between points 1 and 3 of
the test lead connector.
CHARGER VOLTAGE MEASUREMENT
LEVEL 2 - USER'S TECHNICAL DEPARTMENT
Charger voltage measurement = 50.2V + or -
0.2
- ALWAYS CHARGE A BATTERY BEFORE STORING IT.
- STORAGE ROOM TEMPERATURE MUST RANGE FROM 10°C TO 25°C.
- THE BATTERY DISCHARGES TO ITS MIN STORAGE CAPACITY; IT IS IMPERATIVE TO RECHARGE THE BATTERY
BEFORE WORKING AFTER A STORAGE PERIOD OF MORE THAN 4 DAYS.
- AN IMBALANCE CAN BE CREATED BETWEEN THE ELEMENTS DURING STORAGE; THIS IS A NORMAL
PHENOMENON.
IF DISPLAY PROBLEM AND CHARGER VOLTAGE IS OK = RETURN TO DISTRIBUTOR