90
400 1100 POLY5700 / OLIVION
150 / 150P 200 250
"- LEVEL EXPERT- PELLENC POWER TOOL BATTERY" Workshop document
Issue 11/2016 ref. : DOCUMENT ATELIER_BATTERIE_EXP_OUTILS_PELLENC_V2_2016_ENG
BATTERY BEEP DIAGNOSTICS
LEVEL 3 - PELLENC AUTHORISED REPAIRER
FAULTS
CURRENT TOO HIGH
(Overconsumption)
EXCESSIVE
TOOL
TEMPERATURE
SIGNAL
TRIGGER
KICKBACK
(Movement too
fast on X or Y
axis)
2 FAULTS
SIMULTANEOUS
LIXION
TREELION
1 long beep + 1 short
beep
1 long beep + 4
short beeps
1 long beep + 5
short beeps
/
1 long beep + 6 short
beeps
OLIVION / /
HELION / /
EXCELION
1 long beep + 5
short beeps
/
AIRION / /
CULTIVION / /
POLE SELION / /
SELION M12 /
1 long beep + 2
short beeps
SELION C20 /
-1 long beep + 3
short beeps (Y)
-1 long beep + 5
short beeps (X)
150 / 150P / 200 / 250 BATTERIES
400 / 700 / 1100 / POLY5 BATTERIES
FAULTS
CURRENT TOO HIGH
(Overconsumption)
EXCESSIVE TOOL
TEMPERATURE
TRIGGER SIGNAL DURING
USE
(continuity fault
TRIGGER SIGNAL WHEN
SWITCHED ON
(150/150P/250)
(no tool detected)
1 long beep + 4 short beeps 1 long beep + 4 short beeps 1 long beep + 5 short beeps
1 long beep + 6 short
beeps