"- LEVEL EXPERT- PELLENC POWER TOOL BATTERY" Workshop document
Issue 11/2016 ref. : DOCUMENT ATELIER_BATTERIE_EXP_OUTILS_PELLENC_V2_2016_ENG
4. Replacing a battery board
Pre-requisites:
the battery test (Section 1.3) must be satisfactory
the tool must be operational.
the charger must be operational
1. Tool is inoperable and the battery test can be performed and is satisfactory
ĺ5HSODFHWKHEDWWHU\ERDUG
ĺ3HUIRUPEDWWHU\WHVW
2. Tool is inoperable and the battery test cannot be performed
ĺ5HSODFHWKHEDWWHU\ERDUG
ĺ3HUIRUPEDWWHU\WHVW
ĺ !,IEDWWHU\LVIDXOW\UHFRYHUWKHERDUGQHZDQGUHSODFHEDWWHU\DVVHPEO\
3. Charging is not possible
ĺ5HSODFHWKHEDWWHU\ERDUG
ĺ&KDUJHWKHEDWWHU\
ĺ3HUIRUPEDWWHU\WHVW
4. Tool works but the display does not work
ĺ5HSODFHWKHEDWWHU\ERDUG
ĺ3HUIRUPEDWWHU\WHVW
In all cases, the following is mandatory after repairing a battery:
ĺ7HVWLWZLWKDFKDUJHUWRVHHLIFKDUJLQJIXQFWLRQZRUNV
ĺ7HVWLWZLWKDWRROWRVHHLIWRRORXWSXWLVZRUNLQJFRUUHFWO\