EasyManua.ls Logo

pellenc 200 - Pruning Shears Battery Level 2 Message Sheet

pellenc 200
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
95
"- LEVEL EXPERT- PELLENC POWER TOOL BATTERY" Workshop document
Issue 11/2016 ref. : DOCUMENT ATELIER_BATTERIE_EXP_OUTILS_PELLENC_V2_2016_ENG
At the end of the Level 2 diagnostic, the battery switches
to storage mode (discharge to 45%).
Press switch to cancel the discharge: «I» then «0»
6SHFL¿FWR/L[LRQ
BATTERY DIAGNOSTIC WITHOUT SOFTWARE
LE
VEL 3 - PELLENC AUTHORISED REPAIRER
Fault No.
ÀDVKLQJ
Type of battery Explanation of the messages displayed
1
Voltage of the weakest cell in mVolts
2
Voltage of the strongest cell in mVolts
3
Start of charge with a cell under 2.5 V
4
Charger fault
5
/
6
End of charging with excessive difference between cells
7
See message 15.
8
Temperature below 0°C during charging
9
Temperature above 60°C during use
10
Temperature above 45°C during charging
11
End of charge with a cell above 4.23 V
12
Charging stopped with a cell above 4.5V
13
Complete discharge of the battery in use
14
Temp. diff. of more than 10°C between the 2 sensors
15
Fault on balancing resistor and No. concerned
16
Software version of pruning shears and battery
17
Excessive current in the motor control MOSs
18
200 Excessive voltage on power supply
19
200 ,QVXI¿FLHQWYROWDJHRQSRZHUVXSSO\
20
Excessive temperature on motor MOSs
21
Fault on trigger sensor line. The LiXion must be recognized when the battery is started.
22
200 Fault on the motor line
23
Pruning shears software version.
24
Power consumption from start-up
25
Number of hours switched on since entry into service
26
Number of hours switched on since last overhaul
27
150P / 200/250 Excessive current in the motor control MOSs
28
150P / 200/250 Excessive voltage on power supply
29
150P / 200/250 ,QVXI¿FLHQWYROWDJHRQSRZHUVXSSO\
30
150P / 200/250 Excessive temperature on motor MOSs
31
150P / 200/250 Fault on trigger sensor line. Or no shears connected.
32
150P / 200/250 Fault on the motor line
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
BATTERY
End of charging with excessive difference between cellsEnd of charging with excessive difference between cells
See message 15.See message 15.
Temperature below 0°C during chargingTemperature below 0°C during charging
Temperature above 60°C during useTemperature above 60°C during use
Temperature above 45°C during chargingTemperature above 45°C during charging
End of charge with a cell above 4.23 VEnd of charge with a cell above 4.23 V
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
PRUNING
Temperature above 60°C during use
Temperature above 45°C during chargingTemperature above 45°C during charging
End of charge with a cell above 4.23 VEnd of charge with a cell above 4.23 V
Charging stopped with a cell above 4.5VCharging stopped with a cell above 4.5V
Complete discharge of the battery in useComplete discharge of the battery in use
Temp. diff. of more than 10°C between the 2 sensorsTemp. diff. of more than 10°C between the 2 sensors
Fault on balancing resistor and No. concernedFault on balancing resistor and No. concerned
Software version of pruning shears and batterySoftwa
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
SHEARS
Temp. diff. of more than 10°C between the 2 sensorsTemp. diff. of more than 10°C between the 2 sensors
Fault on balancing resistor and No. concernedFault on balancing resistor and No. concerned
Software version of pruning shears and batteryn of pruning shears and battery
ve current in the motor control MOSs
Excessive voltage on power supply
,QVXI¿FLHQWYROWDJHRQSRZHUVXSSO\
Excessive temperature on motor MOSs
Fault on trigger sensor line. The LiXion must be recognized when the battery is started.
PRUNING SHEARS BATTERY LEVEL 2 MESSAGE SHEET
7UHHOLRQ VSHFL¿F EDW-
teries 150 / 150P / 250.

Table of Contents

Related product manuals