EasyManua.ls Logo

Pentair AK110 - AK110 SECURITY SETUP SCREEN NAVIGATION; MASTER AND SERVICE PASSWORD SETUP

Pentair AK110
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
124
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
Main Status Screen
Name:Main Pool
System
Programming
Service
Data ( 8:441 )
Communications
>Security Setup
Wizards
Serial # 123456
Configuration Menu, Security Setup
AK110 Security Setup Screen Navigation
Enter New Password Screen
EnterBack
-Password Setup-
>Master: 0
Service:0
Clear All Passwords
Security Setup, Master Password
Enter Password
Current: 0
0
v-Cancel ^
Enter New Password Screen
-Password Setup-
Master: 8675309
>
Service:0
Clear All Passwords
Security Setup, Service Password
-Confirm Changes -
Clear ALL passwords?
NO:7 9:YES
Clear All Passwords Screen
Press the [9] key to clear the
master and service security
passwords or the [7] key to
cancel.
-Password Setup-
Master: 8675309
Service:1776
>
Clear All Passwords
Security Setup, Clear All Passwords
Enter
9
7
or
Enter
Enter
Enter Password
Current: 0
0
v-Cancel ^
Use the keypad to enter the master
password, up to 9 digits in length.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Use the keypad to enter the service
password, up to 9 digits in length.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Up to two levels of security may be
implemented on the AK110 controller.
The Master password enables access to
all controller functions and menus. A
master password may be implemented
alone, or in conjuntion with a service
password.
The more limited Service password
allows access to sensor calibration screens
from the Main Status Screen. A service
password may be implemented only after
a master password has been implemented.
The password chosen by the user is
simply a number, consisting of a
minimum of one digit and a maximum of
nine digits. There are, however, a few
restrictions when choosing a password:
1. The password may not begin with a
zero [0] as the first digit.
2. The security password must be in the
range of "1" to "999999999", with the
exception of two reserved number ranges.
3. The numbers in the ranges of 9000 to
9100 and 9276100 to 9276110 are
reserved and cannot be used for security
password purposes.
Both passwords may be cleared
simultaneously, by selecting the Clear All
Passwords option on the Security Setup
Screen. This effectively turns off the
AK110 security feature. Alternatively,
entering a passoword of "0" will disable
the password feature.
In order for the passwords to be cleared,
the user must have first entered in a
master password to gain access to the
Security Setup Screen.
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
Main Status, cursor at pH value
Enter new value
Current: 7.67
7.67
v-Cancel ^
Calibration Screen, pH
Enter Password
Enter:
v-Cancel
Password Prompt Screen
Enter Password
Enter: ****
v-Cancel
Password Displayed as Asterisks
Enter
Use Keypad to
Enter Password
>Name:Main Pool
System
Programming
Service
Data ( 8:441 )
Communications
Security Setup
Wizards
Serial # 123456
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
Main Status Screen
Configuration Menu Screen
Enter Password
Enter:
v-Cancel
Password Prompt Screen
Enter Password
Enter: ********
v-Cancel
Password Displayed as Asterisks
Enter
Use Keypad to
Enter Password
Using the AK110 Security Password Feature
Service Password ExampleMaster Password Example
Back
Back Enter
AK110 Security Setup Screen Navigation, Rev 3 21 Aug 2008
10.27

Table of Contents

Related product manuals