108
Name:Main Pool
System
Programming
Service
Data ( 8:441 )
Communications
Security Setup
>Wizards
Serial # 123456
Configuration Menu, Wizards
AK110 Wizards Setup Screen Navigation (1 of 2)
EnterBack
Wizards Setup Screen, Relay 1
>1:pH, Mix Time
2:ORP, Mix Time
3:Not Used
A:Alarm
P:Pager1
P:Pager2
P:Pager3
P:Pager4
Change Control Type
Press -> to toggle
control type
>pH, Mix Time
Change Control Type, Relay 1
Change Control Type
Press -> to toggle
control type
>pH, Cycle Time
Change Control Type, Relay 1
-Confirm Changes
Clear existing setup
and Reassign
NO:7 9:YES
Change Control Confirmation Screen
Press the [9] key to accept the most
recently selected control type
settings or the [7] key to cancel.
Enter
Press the right arrow key [>] to
cycle through the available control
type options.
Wizards Setup Screen, Relay 2
1:pH, Mix Time
>2:ORP, Mix Time
3:Not Used
A:Alarm
P:Pager1
P:Pager2
P:Pager3
P:Pager4
Change Control Type
Press -> to toggle
control type
>
ORP, Mix Time
Change Control Type, Relay 2
Change Control Type
Press -> to toggle
control type
>
ORP, Cycle Time
Change Control Type, Relay 2
-Confirm Changes
Clear existing setup
and Reassign
NO:7 9:YES
Change Control Confirmation Screen
Press the [9] key to accept the most
recently selected control type
settings or the [7] key to cancel.
Press the right arrow key [>] to
cycle through the available control
type options.
Enter
Enter
Wizards Setup Screen, Relay 3
1:pH, Mix Time
2:ORP, Mix Time
>3:Not Used
A:Alarm
P:Pager1
P:Pager2
P:Pager3
P:Pager4
Change Control Type
Press -> to toggle
control type
>Not Used
Change Control Type, Relay 3
Change Control Type
Press -> to toggle
control type
>ProbeClean
Change Control Type, Relay 3
-Confirm Changes
Clear existing setup
and Reassign
NO:7 9:YES
Change Control Confirmation Screen
Press the [9] key to accept the most
recently selected control type
settings or the [7] key to cancel.
Enter
Press the right arrow key [>] to
cycle through the available control
type options.
Wizards Setup Screen, Alarm
1:pH, Mix Time
2:ORP, Mix Time
3:Not Used
>A:Alarm
P:Pager1
P:Pager2
P:Pager3
P:Pager4
Change Control Type
Press -> to toggle
control type
>Alarm
Change Control Type, Alarm
Change Control Type
Press -> to toggle
control type
>Not Used
Change Control Type, Alarm
-Confirm Changes
Clear existing setup
and Reassign
NO:7 9:YES
Change Control Confirmation Screen
Press the [9] key to accept the most
recently selected control type
settings or the [7] key to cancel.
Enter
Press the right arrow key [>] to
cycle through the available control
type options.
Enter
Enter
To Wizards Setup (2 of 2)
Control Options for Relay 1:
1.
2.
3.
pH, Mix Time
pH, Cycle Time
Not Used
Control Options for Relay 2:
1.
2.
3.
4.
5.
6.
ORP, Mix Time
ORP, Cycle Time
Not Used
PPM, Mix Time
PPM, Cycle Time
ORP, Cal Hypo
Control Options for the Alarm:
1.
2.
Alarm
Not Used
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
Main Status Screen
Back
Control Options for Relay 3:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Not Used
ProbeClean
Heater
Alarm Out
pH, Mix Time
pH, Cycle Time
Aux:MakeUp
Daily
Weekly
PPM, Mix Time
PPM, Cycle Time
ORP, Mix Time
ORP, Cycle Time
9
7
or
9
7
or
9
7
or
Enter
9
7
or
AK110 Wizards Setup Screen Navigation, Rev 3 22 Aug 2008
10.23

Table of Contents