60
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
Main Status Screen
Name:Main Pool
System
>Programming
Service
Data ( 8:441 )
Communications
Security Setup
Wizards
Serial # 123456
Configuration Menu, Programming
AK110 Programming Screen Navigation, pH Cycle Time (1 of 2)
EnterBack
>1:pH, Cycle Time
2:ORP, Cycle Time
3:Not Used
A:Alarm
P:Pager1
P:Pager2
P:Pager3
P:Pager4
Programming Setup Screen
pH Cycle, Manual Feed Time
EnterBack
pH Cycle, Proportional Feed Percent
pH Cycle, Acid Feed Setpoint
pH Cycle, Base Feed Setpoint
pH Cycle, Cycle Time
pH Cycle, On Limit
Enter new value
Current: 00:02:00
00:02:00
v-Cancel ^
Manual Feed Time Screen
Use the keypad to enter the manual
chemical feed duration.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter
Proportional Feed Percent Screen
Use the keypad to enter the
proportional feed percentage.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter
Enter new value
Current: 10
10
v-Cancel ^
Enter new value
Current: 7.50
0.00
v-Cancel ^
Use the keypad to enter the pH
setpoint for acid feed control.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter
Acid Feed Setpoint Screen
Enter new value
Current: 0.00
0.00
v-Cancel ^
Use the keypad to enter the pH
setpoint for base feed control.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter
Base Feed Setpoint Screen
Enter
pH Cycle, Independent of SW2
pH Cycle, Feed Off if SW1 is Off
Enter
Cycle Time Screen
Enter new value
Current: 00:01:00
00:01:00
v-Cancel ^
On Limit Screen
Enter new value
Current: 00:00:20
00:00:20
v-Cancel ^
Enter
pH Cycle, Independent of SW1
Enter
Press the [Enter] key to make the
chemical feed dependent or
independent of the status of the flow
switch SW1.
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00<
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20<
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00<
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00
Proportional% 10<
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50<
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00<
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES <
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On –NO <
SetOvrfeed 00:00:00
Overfeed 01:00:00
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-NO <
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
Note:
The relay 1 programming menu
appears in this format only when
relay 1 has been configured for
"pH Cycle Time" control.
Use the keypad to enter the cycle
duration, including both chemical
feed ON time and feed OFF time.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Use the keypad to enter the
maximum chemical feed duration.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Back
pH Cycle, Feed Off if Relay is On
Enter
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2<
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 01:00:00
Use the keypad to enter the number
of a sanitizer control relay to
prevent simultaneous chemical feed.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Feed Off if Relay is On Screen
Enter new value
Current: 2
2
v-Cancel ^
pH Cycle, Feed Off if SW2 is On
Press the [Enter] key to make the
chemical feed dependent or
independent of the status of switch 2
(SW2.)
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-NO
Off if Sw2 On –YES <
SetOvrfeed 00:00:00
Overfeed 01:00:00
pH Cycle, Setpoint Overfeed
Use the keypad to enter the runtime
allowed to reach 5% of setpoint.
Disables relay if setpoint is not met.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter
Enter new value
Current: 00:00:00
00:00:00
v-Cancel ^
Setpoint Overfeed Screen
ManualTime 00:02:00
Proportional% 10
On If pH> 7.50
On If pH< 0.00
Off if RLY On 2
Cycle Time 00:01:00
On Limit 00:00:20
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00<
Overfeed 01:00:00
To pH Cycle Time (2 of 2)
AK110 Programming Screen Navigation, pH Cycle Time, Rev 3 25 Aug 2008
10.7