31
ACU-TROL
®
AK110 Chemical Controller Installation and User's Guide
The Configuration Menu consists of the following:
• Name:Setsupthenameofyouraquaticsystemforeasy
identification during communication and on the wireless
data management system. See pages 56 for Controller
Name Navigation Menu Tree.
• System:Setsuptime,date,weekday,andunitdisplay
(English or Metric). See pages 58 or System Set-up Screen
Navigation.
• Programming:RelayprogrammingforRelays1,2,3,Alarm,andPagers.SeeProgramming
Section for details. See pages 52-109 for Programming Set-up Menus.
• Service:Clearcalibrations,data,orrelaytimersaspartofnormalserviceoperations.
• Data:Sensorreadingsarerecordedatadefault2hoursintodata.Atotalof441linesofdatacanbe
stored. Press the down arrow key to view data. See page 114 for Data Screen Navigation.
• Communications:Setupmodems,pagernumbersandoremailaddresses.Seepages102-105for
Programming Screen Navigation Pager 1. See page 116 for Communications Screen for Dail-up and
Internet Modems. See pages 106 for Programming Screen Navigation Email.
• SecuritySetup:Setsuppasswords,clearspasswords,andresetsallsettingstofactorydefaults.
See pages 126 for Security Setup Screen Naviagtions.
• Wizards:Selectpre-writtenprogramsforcommonControllerapplications.
See pages 110 for Wizards Setup Screen Navigation.
• Serial#:Viewtheserialnumberhere.Theserialnumberisrequiredwhenrequestingsupport.
Note:
When entering pulses per gallon the Controller will only
update this measurement once every 10 seconds.
Conguration Menu
To clear the Total, for any switch place the cursor on Clear
and press ENTER.
Conguration Menu Screen
>Name:Main Pool
System
Programming
Service
Data ( 8:441 )
Communications
Security Setup
Wizards
Serial # 123456
Flow Switch 2 Setup, Clear Counter
Flow Switch #2
SW2 K => 8.5 pul/g
g/m = 35
Total = 0 >Clear