90
10.16
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
Aux:MakeUp-OFF
SW1OFFSW2OFF
Main Status Screen
Name:Main Pool
System
>Programming
Service
Data ( 8:441 )
Communications
Security Setup
Wizards
Serial # 123456
Configuration Menu, Programming
AK110 Programming Screen Navigation, Aux: Make-Up (Auto Fill)
EnterBack
1:pH, Mix Time
2:ORP, Mix Time
>3:Aux:MakeUp
A:Alarm
P:Pager1
P:Pager2
P:Pager3
P:Pager4
Programming Setup Screen
Aux:MakeUp, Manual Cycle Time
EnterBack
Enter new value
Current: 00:02:00
00:02:00
v-Cancel ^
Manual Cycle Time Screen
Use the keypad to enter the manual
make-up relay on-time duration.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter
Enter
Aux:MakeUp, Overfeed
Press the [Enter] key to make the
make-up relay operation dependent
upon whether switch 2 (SW2) is on
or not.
Note:
The relay 3 programming menu
appears in this format only when
relay 3 has been configured for
"Aux:MakeUp" control.
Aux:MakeUp, Not On if SW2 is Off
Enter
Aux:MakeUp, Minimum Time On
Aux:MakeUp, Minimum Time Off
Enter new value
Current: 00:00:30
00:00:30
v-Cancel ^
Use the keypad to enter the time
delay between the setpoint trigger
and the make-up relay start.
Press the [Enter] key to confirm or
the down arrow key to cancel.
On Delay Screen
Aux:MakeUp, On if SW2 is Off
ManualTime 00:02:00<
On if Sw2 Off-No
On if Sw2 On -YES
On DELAY 00:00:30
MinTime On 00:02:00
MinTimeOff 00:05:00
Overfeed 01:00:00
ManualTime 00:02:00
On if Sw2 Off-NO <
On if Sw2 On -YES
On DELAY 00:00:30
MinTime On 00:02:00
MinTimeOff 00:05:00
Overfeed 01:00:00
Aux:MakeUp, On if SW2 is On Aux:MakeUp, Not On if SW2 is On
Enter
Aux:MakeUp, On Delay
Enter
Enter new value
Current: 00:02:00
00:02:00
v-Cancel ^
Use the keypad to enter the
minimum amount of time the make-
up relay will be turned on.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Minimum Time On Screen
Enter
Enter new value
Current: 00:05:00
00:05:00
v-Cancel ^
Minimum Time Off Screen
Use the keypad to enter the amount
of time the relay will be held off
before it is allowed to turn on again.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter new value
Current: 01:00:00
01:00:00
v-Cancel ^
Overfeed Screen
Use the keypad to enter the daily
maximum accumulated make-up
relay on-time.
Press the [Enter] key to confirm or
the down arrow key to cancel.
ManualTime 00:02:00
On if Sw2 Off-YES <
On if Sw2 On -YES
On DELAY 00:00:30
MinTime On 00:02:00
MinTimeOff 00:05:00
Overfeed 01:00:00
ManualTime 00:02:00
On if Sw2 Off-NO
On if Sw2 On -YES <
On DELAY 00:00:30
MinTime On 00:02:00
MinTimeOff 00:05:00
Overfeed 01:00:00
ManualTime 00:02:00
On if Sw2 Off-NO
On if Sw2 On -NO <
On DELAY 00:00:30
MinTime On 00:02:00
MinTimeOff 00:05:00
Overfeed 01:00:00
ManualTime 00:02:00
On if Sw2 Off-NO
On if Sw2 On -YES
On DELAY 00:00:30<
MinTime On 00:02:00
MinTimeOff 00:05:00
Overfeed 01:00:00
ManualTime 00:02:00
On if Sw2 Off-NO
On if Sw2 On -YES
On DELAY 00:00:30
MinTime On 00:02:00<
MinTimeOff 00:05:00
Overfeed 01:00:00
Press the [Enter] key to make the
make-up relay operation dependent
upon whether switch 2 (SW2) is off
or not.
ManualTime 00:02:00
On if Sw2 Off-NO
On if Sw2 On -YES
On DELAY 00:00:30
MinTime On 00:02:00
MinTimeOff 00:05:00<
Overfeed 01:00:00
ManualTime 00:02:00
On if Sw2 Off-NO
On if Sw2 On -YES
On DELAY 00:00:30
MinTime On 00:02:00
MinTimeOff 00:05:00
Overfeed 01:00:00<
Back
AK110 Programming Screen Navigation, Aux:MakeUp, Rev 3 22 Aug 2008