Press the [Enter] key to set the
AKColor™ measurment cycle time
from 3 minutes to 15 minutes, in 1
minute increments.
AK110 AKColor™ Screen Navigation
The AK110 controller may be configured to interface with the Acu-Trol AKColor™
Colorimetric Sensor. This requires the installation of an optional colorimetric PPM-
capable sensor card in place of the standard pH/ORP/Temperature sensor card.
The AK110, when interfaced to an AKColor™ sensor, may only make measurements
for "free" chlorine PPM, even if the AKColor™ is equipped to make "total" chlorine
PPM measurements as well.
When the AKColor™ with ORP backup sensor card is installed in the controller, it is
automatically detected upon power-up. The type of sensor card detected will
determine which sensor readings or menu options are available to the user. The
variations of the user interface with an AKColor™ with ORP backup sensor card are
outlined on this page.
A primary difference is the supplanting of the default ORP measurement-based control
with PPM measurement-based control of relay 2. With an AKColor™ with ORP
backup sensor card installed, the AK110 will control relay 2 based upon PPM
measurements as long as the DPD level is estimated to be above 0%. When the
estimated DPD level drops to 0%, relay 2 will instead be controlled based upon ORP
measurements.
Configuration options for the AKColor™ sensor are made available on the
Configuration Menu Screen.
The status of the AKColor™ sensor is displayed on the AKColor™ Status Screen,
which is easily accessible from the Main Status Screen.
Main Status Screen, AKColor™
>Name:Main Pool
System
Programming
Service
Data ( 8:441 )
Communications
Security Setup
Wizards
AKCOLOR
Configuration Menu, Controller Name
pH > 7.67-OFF 7.50s
PPM 2.65-OFF 2.00s
_____
69.0f SW1OFFSW2OFF
AKColor™ Status Screen
FREE= 2.65 75/320
MixingDPD
lvl= 90%
CLRv= 3.48 v= 1.98
Name:Main Pool
System
Programming
Service
>Data ( 8:441 )
Communications
Security Setup
Wizards
AKCOLOR
Serial # 123456
Configuration Menu, Data Data Display Screen
07/04 pH PPM Temp
12:00 7.53 2.88 76.
10:00 7.45 3.02 75.
08:00 7.42 3.14 75.
06:00 7.45 2.06 76.
04:00 7.59 1.95 77.
02:00 7.60 1.81 76.
00:00 7.64 1.72 75.
22:00 7.68 1.99 75.
Name:Main Pool
System
Programming
Service
Data ( 8:441 )
Communications
Security Setup
Wizards
>AKCOLOR
Serial # 123456
Configuration Menu, AKColor™
Enter
Back
AKColor™ Config, DPD Level 0%
>DPD Level: 0%
TYPE: Free Only
Cycle (min): 4
Manual Control
Enter
AKColor™ Config, DPD Level 100%
>DPD Level: 100%
TYPE: Free Only
Cycle (min): 4
Manual Control
AKColor™ Config, DPD Level 0%
DPD Level: 0%
>TYPE: Free Only
Cycle (min): 4
Manual Control
AKColor™ Config, 4 Minute Cycle
DPD Level: 0%
TYPE: Free Only
>Cycle (min): 4
Manual Control
Enter
AKColor™ Config, 5 Minute Cycle
DPD Level: 0%
TYPE: Free Only
Cycle (min): 5
Manual Control
AKColor™ Config, Manual Control
DPD Level: 0%
TYPE: Free Only
Cycle (min): 4
>Manual Control
Enter
AKColor™ Manual Control Screen
AKCOLOR Ctl: v=1.98
0=BUFF 1=DPD
2=Flow 3=OFF
4=TOT 8=AllOn
Colorimetric PPM readings are
displayed in the third column of the
Data Display Screen.
Press the [Enter] key to set the
estimated remaining DPD reagent
level from 0% to 100%, in varying
increments.
The AKColor™ Status Screen
displays the sensor status, clear and
DPD-mixed voltage levels, and the
calculated free chlorine PPM.
The AK110 controller is limited to
taking "free" chlorine PPM
measurements with the AKColor™
sensor.
The AKColor™ Manual Control
Screen allows for manual user control
of the AKColor™ solenoids for setup
and troubleshooting purposes.
Back
Main Status Screen, AKColor™ Empty
pH > 7.67-OFF 7.50s
PPM 2.65-OFF err
_____
69.0f SW1OFFSW2OFF
Main Status Screen, ORP Shown
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
The AK110 Controller and the AKColor™ Sensor Viewing PPM and ORP Measurements and Setpoints
PPM measurement and "error
condition" shown on the display
second row indicates an empty bottle.
ORP measurement and setpoint
shown on the display second row as
normal. ORP now controls relay 2.
When an AKColor™ with ORP backup sensor module is installed, the second row of
the display will alternate between showing PPM and ORP information. When
chemicals are estimated to be present in the AKColor™, the PPM measurement and
setpoint will both be displayed.
When the AK110 estimates that the DPD and buffer solutions have been consumed,
the PPM measurement is shown, but the setpoint displays an error condition.
Main Status Screen, PPM Shown
pH > 7.67-OFF 7.50s
PPM 2.65-OFF 2.00s
_____
69.0f SW1OFFSW2OFF
Main Status Screen, ORP Shown
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
PPM measurement and setpoint
shown on the second display row.
Relay 2 is controlled by PPM.
ORP measurement and setpoint
shown on the second display row.
Relay 2 is still controlled by PPM.
AK110 AKColor Screen Navigation, Rev 3 21 Aug 2008