EasyManua.ls Logo

Pentair AK110 - Page 51

Pentair AK110
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
p
H, Mix TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, Relay 1 (pH)
P
ager4 TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, Pager / E-mail 4
P
ager3 TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, Pager / E-mail 3
Timer Screen, Pager / E-mail 2
P
ager2 TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, Pager / E-mail 1
P
ager1 TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Alarm TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, Alarm
Relay3 TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, Relay 3 (Optional)
AK110 Relay and Alarm Timer Screen Navigation
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
Main Status, cursor at pH value
Main Status, pH Relay Status
pH 7.67>OFF 7.50s
ORP 490 -OFF 700s
_____
69.0f SW1OFFSW2OFF
Main Status, ORP Relay Status
pH 7.67-OFF 7.50s
ORP 490 >OFF 700s
_____
69.0f SW1OFFSW2OFF
Back
p
H, Mix TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, pH Relay
O
RP, Mix TMR00:00:00
>TD00:00:00
CNT: 0 S 00:00:00
STS:OFF TOT 0:00
Timer Screen, Relay 2 (ORP)
8
7
6
5
4
3
2
1
pH, Mix TMR00:09:01
>TD00:23:45
CNT: 1234 S 02:34:56
STS:OFF TOT 12:34
Timer Screen, Today (TD)
pH, Mix TMR00:09:01
TD00:23:45
CNT:>1234 S 02:34:56
STS:OFF TOT 12:34
Timer Screen, Count (CNT)
pH, Mix TMR00:09:01
TD00:23:45
CNT: 1234>S 02:34:56
STS:OFF TOT 12:34
Timer Screen, Set Overfeed (S)
pH, Mix TMR00:09:01
TD00:23:45
CNT: 1234 S 02:34:56
STS:OFF >TOT 12:34
Timer Screen, Total Time (TOT)
Enter
Enter
Enter
Enter
pH, Mix TMR00:09:01
>TD00:00:00
CNT: 1234 S 02:34:56
STS:OFF TOT 12:34
Reset Timer, Today (TD)
pH, Mix TMR00:09:01
TD00:23:45
CNT:> 0 S 02:34:56
STS:OFF TOT 12:34
Reset Timer, Count (CNT)
pH, Mix TMR00:09:01
TD00:23:45
CNT: 1234>S 00:00:00
STS:OFF TOT 12:34
Reset Timer, Set Overfeed (S)
Reset Timer, Total Time (TOT)
pH, Mix TMR00:09:01
TD00:23:45
CNT: 1234 S 02:34:56
STS:OFF >TOT 0:00
Cycling Through the Timer Screens
There are a total of eight Timer
Screens. One Timer Screen is
available for each of the three
relays, one for the front panel
alarm, and one for each of the four
pager/e-mail devices.
If relay 3 has not been configured,
the Timer Screen for that relay
will appear blank.
From any Timer Screen, press the
[Back] key to return to the Main
Status Screen.
The eight Timer Screens are
arranged in a specific sequence.
Press the up or down arrow keys
to cycle from one Timer Screen
to another.
Each of the Timer Screens
corresponds to a number, from
[1] to [8]. To jump directly to a
specific Timer Screen, press the
keypad number associated with
that device. For instance, to jump
to the Alarm Timer Screen, press
the [4] key.
Navigating Within the Timer Screen
Each of the four selectable timers can be
manually reset to zero. To reset a specific
timer, press the right arrow key to position
the cursor next to the timer, then press the
[Enter] key.
From any Timer Screen, press the [Back] key
to return to the Main Status Screen.
Accessing the Timer Screens
Timer Screens can be accessed from the
Main Status Screen. Press the right arrow
key to move the cursor to the status indicator
of relay 1, 2, or 3 (if configured.) Press the
right arrow key again to access the pH Timer
Screen. From there, press the up or down
arrow keys to navigate to additional timer
screens (see "Cycling Through the Timer
Screens" at right).
Use the right arrow key to navigate within
the Timer Screen. There four timer cursor
positions to cycle through:
Accumulated on-time for the day.
Number of relay cycles since last reset.
Relay on-time without reaching setpoint.
Total on-time since the last reset.
TD:
CNT:
S:
TOT:
Back
AK110 Relay and Alarm Timer Screen Navigation, Rev 3 21 Aug 2008

Table of Contents