93
pH > 7.67-OFF 7.50s
ORP 490 -OFF 700
Daily -OFF
69.0f SW1OFFSW2OFF
Main Status Screen
Name:Main Pool
System
>Programming
Service
Data ( 8:441 )
Communications
Security Setup
Wizards
Serial # 123456
Configuration Menu, Programming
AK110 Programming Screen Navigation, Daily Event
EnterBack
1:pH, Mix Time
2:ORP, Mix Time
>3:Daily
A:Alarm
P:Pager1
P:Pager2
P:Pager3
P:Pager4
Programming Setup Screen
Daily Event, Manual Cycle Time
EnterBack
Enter new value
Current: 00:02:00
00:02:00
v-Cancel ^
Manual Cycle Time Screen
Use the keypad to enter the manual
relay on-time duration.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter
Enter
Enter
Press the [Enter] key to make the
relay operation dependent or
independent of the status of switch 2
(SW2.)
Note:
The relay 3 programming menu
appears in this format only when
relay 3 has been configured for
"Daily" control.
Daily Event, Off if Time is After
Enter
Daily Event, Minimum Time Off
Daily Event, Relay On if SW2 is On
Enter new value
Current: 00:02:00
00:02:00
v-Cancel ^
Use the keypad to enter the
maximum relay on-time duration.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Use the keypad to enter the time
after which the relay will turn off.
Press the [Enter] key to confirm or
the down arrow key to cancel.
On Calculated Time Screen
Off if Time is After Screen
Daily Event, Off if Time is Before Off if Time is Before Screen
Enter
Daily Event, On Calculated Time
Enter
Enter new value
Current: 00:05:00
00:05:00
v-Cancel ^
Minimum Time Off Screen
Daily Event, Independent of SW2
Use the keypad to enter the amount
of time the relay will be held off
before it is allowed to turn on again.
Press the [Enter] key to confirm or
the down arrow key to cancel.
ManualTime 00:02:00<
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00
OnCTime 00:02:00
MinTimeOff 00:05:00
On if Sw2 On -YES
Off if Sw1 Off-YES
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02<
OffIfTime< 01:01:00
OnCTime 00:02:00
MinTimeOff 00:05:00
On if Sw2 On -YES
Off if Sw1 Off-YES
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00<
OnCTime 00:02:00
MinTimeOff 00:05:00
On if Sw2 On -YES
Off if Sw1 Off-YES
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00
OnCTime 00:02:00<
MinTimeOff 00:05:00
On if Sw2 On -YES
Off if Sw1 Off-YES
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00
OnCTime 00:02:00
MinTimeOff 00:05:00<
On if Sw2 On -YES
Off if Sw1 Off-YES
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00
OnCTime 00:02:00
MinTimeOff 00:05:00
On if Sw2 On –YES <
Off if Sw1 Off-YES
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00
OnCTime 00:02:00
MinTimeOff 00:05:00
On if Sw2 On –NO <
Off if Sw1 Off-YES
Enter new value
Current: 01:01:00
01:01:00
v-Cancel ^
Enter new value
Current: 01:01:02
01:01:02
v-Cancel ^
Use the keypad to enter the time
before which the relay will turn off.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Back
Enter
Press the [Enter] key to make the
relay operation dependent or
independent of the status of the flow
switch SW1.
Daily Event, Relay Off if SW1 is Off Daily Event, Independent of SW1
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00
OnCTime 00:02:00
MinTimeOff 00:05:00
On if Sw2 On -YES
Off if Sw1 Off-YES <
ManualTime 00:02:00
** ON **
OffIfTime> 01:01:02
OffIfTime< 01:01:00
OnCTime 00:02:00
MinTimeOff 00:05:00
On if Sw2 On -YES
Off if Sw1 Off-NO <
AK110 Programming Screen Navigation, Daily Event, Rev 3 22 Aug 2008