MEP-7000
5
6 7 8
5
6 7 8
A
B
C
D
E
F
D201
LV
StatusLED
Device
diagnosis
Defective device Remarks
How to check
Judgment
Main CPU
(SOUTH CPU),
flash ROM, or SDRAM
• Defective CPU
• Defective bus (Because of equal-length
wiring, even if one of the cables is defective,
a device connected to that bus becomes
unstable.)
*In a case of a failure in the line from the
CPU to the SDRAM CS, operation of the
LEDs is irregular.
S3
AUDIO DSP
NG
Audio DSP
Configuration of the AUDIO-DSP is not
completed.
S0
×
(Unlit)
(Flashes 3 times)
S4
FPGA NG
(Flashes 4 times)
(Flashes 5 times)
S5
USB
CONTROLLER
NG
FPGA
Configuration of the FPGA is not completed.
*Note that communication with the
main
CPU
(SOUTH CPU) is normal even if the 16-MHz
clock (for audio sync) is defective.
*If the FPRGM line is defective.
(Communication
between units)
SERVO
DRIVE 2
NG
Servo drive 2
USB controller
Configuration of the USB controller is not
completed.
ATAPI 1 communication is not possible with
the drive 2 optical disc controller.
SERVO
DRIVE 1
NG
S8
(Flashing continuously)
(Flashes 6 times)
(Flashes 7 times)
S7
S6
SUD2
(Lit)
Normal startup
SUD1
(Flashing asynchronously)
Transmission of updater files to the control
unit (NORTH CPU) is in progress.
*Currently, the Firmware Updating Program
(DJS) method is not supported.
×
(Lit for 2 sec)
SOK
Writing of updater-file data to the flash
memories of the drive unit (SOUTH CPU/
Servo 1/Servo 2) is in progress.
*Currently, the Firmware Updating Program
(DJS) method is not supported.
(During updating)
Communication with the control unit
(NORTH Unit) is not possible.
Servo drive 1
ATAPI 1 communication is not possible with
the drive 1 optical disc controller.
Memo: If several devices are in failure, the least critical failure is indicated with the LEDs.
Memo: If the S5 step is successfully cleared, the startup sequence will not be interrupted even if not all devices
operate properly.
Memo: It may take dozens of seconds for the unit to determine OK or NG for devices other than the AUDIO
DSP/FPGA, because of retries.

Table of Contents

Other manuals for Pioneer MEP-7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pioneer MEP-7000 and is the answer not in the manual?

Pioneer MEP-7000 Specifications

General IconGeneral
Frequency range4 - 20000 Hz
Channels quantity- channels
Digital sound processing- bit
Total Harmonic Distortion (THD)0.006 %
Dimensions (WxDxH)483 x 325 x 91 mm
Power consumption (typical)33 W
Weight and Dimensions IconWeight and Dimensions
Weight6100 g

Related product manuals