10-57. TROUBLESHOOTING.
TABLE X-XI. FUEL PRESSURE GAUGE
Trouble Cause Remedy
No fuel pressure indication. Fuel valve stuck. Check valve.
No fuel in tanks. Check fuel, full.
Defective fuel pump. Check pump for pressure
buildup. Check diaphragm
and relief valve in engine
pump. Check for obstruction
in electric pump. Check
bypass valve. Air leak in
intake lines.
Defective gauge. Replace gauge.
Pressure low or Obstruction in inlet Trace lines and locate
pressure surges. side of pump. obstruction.
Faulty bypass valve. Replace.
Faulty diaphragm. Replace or rebuild pump.
Needle fluctuation. Purge dome or pump Remove and empty.
filled with fuel.
Air in line. Loosen line at gauge, turn on
electric pump. Purge line of
air and retighten.
High fuel pressure Fuel in line expanding Normal.
with engine shut off due to heat build up in
right after flight. cowling.
10-58. REMOVAL AND REPLACEMENT. (Refer to Paragraph 10-78 of this section.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Piper TURBO ARROW III and is the answer not in the manual?

Piper TURBO ARROW III Specifications

General IconGeneral
ManufacturerPiper Aircraft
ModelTurbo Arrow III
Horsepower200 hp
Max Takeoff Weight2, 900 lbs
Fuel Capacity72 gallons
Service Ceiling20, 000 ft
Seating Capacity4
TypeSingle-engine piston
PropellerConstant-speed
Landing Distance1, 200 ft

Related product manuals