Figure 11-9. Installing Rectifiers
11-14. REMOVING RECTIFIERS. After cutting the lead from the malfunctioning rectifier, position the
fixture with the rectifier to be removed over the fixture anvil.
Position the removing adapter SP-3821 around the rectifier. Rotate the threaded screw clockwise. As the
screw approaches the removing adapter, guide its shank into the hole in the end of the screw.
Just before the downward motion of the screw bottoms, recheck the adapter to be sure it is in the proper
position. Then continue to rotate the screw until the rectifier is free of the end shield or heat sink.
Reverse the screw by rotating it counterclockwise. Remove adapter and old rectifier.
Remove the end shield assembly from the fixture and position SP-3820 installing support on the fixture
anvil.
11-15. INSTALLING RECTIFIERS. Start the new rectifier as squarely as possible into the hole the old
rectifier was removed from after first checking to be sure it is of the proper polarity. The negative rectifiers are
marked with black numerals and the positive with red.
Reposition the end shield in the fixture, locating the hole over the installing support.
With the installing adapter SP-3818 positioned on the rectifier, rotate the screw clockwise.
Guide the shank of the adapter into the screw. Continue to move the screw downward until just before
bottoming.
CAUTION
Check carefully to be certain that the adapter is positioned properly over the
rectifier and the rectifier is started squarely in the hole.
Rotate the screw clockwise pressing the rectifier in place until it bottoms. When the rectifier bottoms, it
can easily be felt. Remove the end shield assembly from the fixture and inspect to see that rectifier is installed
properly.
Revised: 2/13/89
2H1
CHEROKEE ARROW III SERVICE MANUAL
ELECTRICAL SYSTEM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Piper TURBO ARROW III and is the answer not in the manual?

Piper TURBO ARROW III Specifications

General IconGeneral
ManufacturerPiper Aircraft
ModelTurbo Arrow III
Horsepower200 hp
Max Takeoff Weight2, 900 lbs
Fuel Capacity72 gallons
Service Ceiling20, 000 ft
Seating Capacity4
TypeSingle-engine piston
PropellerConstant-speed
Landing Distance1, 200 ft

Related product manuals