EasyManua.ls Logo

Planmeca ProMax X-ray - User Manual

Planmeca ProMax X-ray
346 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ProMax X-ray
with Dimax3
TECHNICAL MANUAL
Publication number 10010812
Version 10
Published 2006-03
En

Table of Contents

Other manuals for Planmeca ProMax X-ray

Question and Answer IconNeed help?

Do you have a question about the Planmeca ProMax X-ray and is the answer not in the manual?

Summary

ProMax X-ray with Dimax3

TECHNICAL MANUAL

Main title of the document.

Chapter A GENERAL & TECHNICAL DATA

WARNINGS AND CAUTIONS

Critical safety warnings and precautions for servicing the unit.

MANUAL VERSIONS

Information on the manual's validity and software version.

SYMBOLS

Explanation of symbols used throughout the manual.

TECHNICAL SPECIFICATIONS

Detailed technical data and parameters of the X-ray unit.

USER’S STATEMENT FOR PROMAX X-RAY

Statement regarding radiation leakage and measurement criteria.

HANDLING PRECAUTIONS FOR PCB’S AND SOFTWARE CHIPS

Safety guidelines for handling electronic components.

EMC INFORMATION

Electromagnetic compatibility declarations and guidance.

Chapter B INFORMATION DISPLAYS

GENERAL ABOUT INFORMATION DISPLAYS

Overview of the unit's information display system and navigation.

USER PREFERENCE SETTINGS

Configuration options for user-specific settings and preferences.

FEATURE PROGRAM CONTROL

Enabling or disabling specific features and programs on the unit.

SPECIAL FUNCTIONS

Access to special operation modes and test functions.

SERVICE SETTINGS

Password-protected settings for service personnel and maintenance.

TECHNICAL CALIBRATIONS

Procedures for calibrating various unit functions.

TROUBLESHOOTING

Guidance for diagnosing and resolving operational issues.

ENTERING THE PASSWORD

Procedure for accessing password-protected modes.

Chapter C ERROR MESSAGES

HELP AND ERROR MESSAGE SHORT-FORM TABLES

Reference tables for error codes and their explanations.

Motorized motion related errors (2 xx)

Explanations and solutions for errors related to unit movement.

X-ray generation related errors (3 xx)

Explanations and solutions for errors in X-ray generation.

Feedback errors (4 xx)

Explanations and solutions for feedback system errors.

Power supply related errors (5 xx)

Explanations and solutions for power supply issues.

Communication errors (6 xx)

Explanations and solutions for communication failures.

Calibration errors (7 xx)

Explanations and solutions for calibration-related errors.

System conflicts (8 xx)

Explanations and solutions for system conflict errors.

Infrastructure errors (9 xx)

Explanations and solutions for infrastructure-related errors.

Chapter D PREVENTIVE MAINTENANCE

SYSTEM MAINTENANCE

Procedures for maintaining the X-ray unit's systems.

PREVENTIVE MAINTENANCE CHECKS

Regular checks to ensure optimal equipment performance.

MECHANICAL CHECKS

Inspection of mechanical components for proper function.

Chapter E C-ARM AND IMAGING ARM

PANORAMIC BEAM AND PATIENT POSITIONING MECHANISM ADJUSTMENT

Procedures for adjusting beam and positioning mechanisms.

REQUIRED TOOLS

List of tools needed for C-arm and imaging arm adjustments.

Checking the panoramic beam position

Verifying the alignment of the panoramic X-ray beam.

Adjusting the sensor head angle

Procedure to set the correct angle for the sensor head.

Primary collimator angle adjustment

Adjusting the angle of the primary collimator for proper beam alignment.

Panoramic beam adjustment

Procedures for adjusting panoramic beam horizontal and vertical positions.

X-ray unit with fixed primary collimator - primary collimator adjustment

Specific adjustment for units with fixed primary collimators.

Beam check

Testing the X-ray unit's collimation and beam alignment.

Calibrating panoramic sensor head

Steps for calibrating the panoramic sensor head.

Checking the adjustments

Verifying the overall alignment after adjustments.

Patient positioning mechanism adjustment

Adjusting the mechanism for correct patient positioning.

Checking the eccentricity of the rotation movement

Checking for rotational movement errors.

OTHER ADJUSTMENTS AND CALIBRATIONS

Additional calibration and adjustment procedures.

Calibrating the elbow arm and C-arm gear ratios

Calibrating gear ratios for arm movement.

Adjustment of tomo mode patient positioning lights

Aligning the positioning lights for Tomo mode.

Calibrating the panoramic dynamic exposure control (DEC)

Calibrating the DEC function for exposure control.

REMOVING THE COVERS

Procedures for safely removing unit covers for access.

REPLACING THE SENSOR HEAD

Step-by-step guide for replacing the sensor head.

REPLACING PCBS

Instructions for replacing printed circuit boards.

REPLACING TUBE HEAD

Procedure for replacing the X-ray tube head assembly.

Chapter F PATIENT SUPPORT ARM

ADJUSTMENTS

Adjustments related to the patient support arm.

REMOVING THE COVERS

Procedures for removing covers of the patient support arm.

REPLACING THE GUI SOFTWARE

Instructions for updating or replacing GUI software.

REPLACING PCBS

Procedures for replacing PCBs within the patient support arm.

Chapter G COLUMN

ADJUSTMENTS

Adjustments related to the unit's column assembly.

REMOVING THE COVERS

Procedures for removing column covers for access.

REPLACING THE COLUMN MOTOR

Step-by-step guide for replacing the column motor.

REPLACING;UPGRADING SOFTWARE

Procedures for replacing or upgrading unit software.

REPLACING THE BATTERY ON THE RTC PCB

Instructions for replacing the RTC PCB battery.

REPLACING PCBS

Procedures for replacing PCBs within the column assembly.

Chapter H CEPHALOSTAT

ADJUSTMENTS AND CALIBRATIONS

Procedures for adjusting and calibrating the cephalostat.

REMOVING AND ATTACHING THE SECOND PRIMARY COLLIMATOR

Procedures for servicing the secondary collimator.

DETACHING AND ATTACHING THE SENSOR HEAD

Procedures for detaching and attaching the sensor head.

REMOVING THE HOUSINGS AND COVERS

Procedures for removing cephalostat housings and covers.

REPLACING PCBS

Procedures for replacing PCBs in the cephalostat.

Chapter I DIAGRAMS

WIRING DIAGRAM

Electrical wiring diagrams for unit components.

Summary

ProMax X-ray with Dimax3

TECHNICAL MANUAL

Main title of the document.

Chapter A GENERAL & TECHNICAL DATA

WARNINGS AND CAUTIONS

Critical safety warnings and precautions for servicing the unit.

MANUAL VERSIONS

Information on the manual's validity and software version.

SYMBOLS

Explanation of symbols used throughout the manual.

TECHNICAL SPECIFICATIONS

Detailed technical data and parameters of the X-ray unit.

USER’S STATEMENT FOR PROMAX X-RAY

Statement regarding radiation leakage and measurement criteria.

HANDLING PRECAUTIONS FOR PCB’S AND SOFTWARE CHIPS

Safety guidelines for handling electronic components.

EMC INFORMATION

Electromagnetic compatibility declarations and guidance.

Chapter B INFORMATION DISPLAYS

GENERAL ABOUT INFORMATION DISPLAYS

Overview of the unit's information display system and navigation.

USER PREFERENCE SETTINGS

Configuration options for user-specific settings and preferences.

FEATURE PROGRAM CONTROL

Enabling or disabling specific features and programs on the unit.

SPECIAL FUNCTIONS

Access to special operation modes and test functions.

SERVICE SETTINGS

Password-protected settings for service personnel and maintenance.

TECHNICAL CALIBRATIONS

Procedures for calibrating various unit functions.

TROUBLESHOOTING

Guidance for diagnosing and resolving operational issues.

ENTERING THE PASSWORD

Procedure for accessing password-protected modes.

Chapter C ERROR MESSAGES

HELP AND ERROR MESSAGE SHORT-FORM TABLES

Reference tables for error codes and their explanations.

Motorized motion related errors (2 xx)

Explanations and solutions for errors related to unit movement.

X-ray generation related errors (3 xx)

Explanations and solutions for errors in X-ray generation.

Feedback errors (4 xx)

Explanations and solutions for feedback system errors.

Power supply related errors (5 xx)

Explanations and solutions for power supply issues.

Communication errors (6 xx)

Explanations and solutions for communication failures.

Calibration errors (7 xx)

Explanations and solutions for calibration-related errors.

System conflicts (8 xx)

Explanations and solutions for system conflict errors.

Infrastructure errors (9 xx)

Explanations and solutions for infrastructure-related errors.

Chapter D PREVENTIVE MAINTENANCE

SYSTEM MAINTENANCE

Procedures for maintaining the X-ray unit's systems.

PREVENTIVE MAINTENANCE CHECKS

Regular checks to ensure optimal equipment performance.

MECHANICAL CHECKS

Inspection of mechanical components for proper function.

Chapter E C-ARM AND IMAGING ARM

PANORAMIC BEAM AND PATIENT POSITIONING MECHANISM ADJUSTMENT

Procedures for adjusting beam and positioning mechanisms.

REQUIRED TOOLS

List of tools needed for C-arm and imaging arm adjustments.

Checking the panoramic beam position

Verifying the alignment of the panoramic X-ray beam.

Adjusting the sensor head angle

Procedure to set the correct angle for the sensor head.

Primary collimator angle adjustment

Adjusting the angle of the primary collimator for proper beam alignment.

Panoramic beam adjustment

Procedures for adjusting panoramic beam horizontal and vertical positions.

X-ray unit with fixed primary collimator - primary collimator adjustment

Specific adjustment for units with fixed primary collimators.

Beam check

Testing the X-ray unit's collimation and beam alignment.

Calibrating panoramic sensor head

Steps for calibrating the panoramic sensor head.

Checking the adjustments

Verifying the overall alignment after adjustments.

Patient positioning mechanism adjustment

Adjusting the mechanism for correct patient positioning.

Checking the eccentricity of the rotation movement

Checking for rotational movement errors.

OTHER ADJUSTMENTS AND CALIBRATIONS

Additional calibration and adjustment procedures.

Calibrating the elbow arm and C-arm gear ratios

Calibrating gear ratios for arm movement.

Adjustment of tomo mode patient positioning lights

Aligning the positioning lights for Tomo mode.

Calibrating the panoramic dynamic exposure control (DEC)

Calibrating the DEC function for exposure control.

REMOVING THE COVERS

Procedures for safely removing unit covers for access.

REPLACING THE SENSOR HEAD

Step-by-step guide for replacing the sensor head.

REPLACING PCBS

Instructions for replacing printed circuit boards.

REPLACING TUBE HEAD

Procedure for replacing the X-ray tube head assembly.

Chapter F PATIENT SUPPORT ARM

ADJUSTMENTS

Adjustments related to the patient support arm.

REMOVING THE COVERS

Procedures for removing covers of the patient support arm.

REPLACING THE GUI SOFTWARE

Instructions for updating or replacing GUI software.

REPLACING PCBS

Procedures for replacing PCBs within the patient support arm.

Chapter G COLUMN

ADJUSTMENTS

Adjustments related to the unit's column assembly.

REMOVING THE COVERS

Procedures for removing column covers for access.

REPLACING THE COLUMN MOTOR

Step-by-step guide for replacing the column motor.

REPLACING;UPGRADING SOFTWARE

Procedures for replacing or upgrading unit software.

REPLACING THE BATTERY ON THE RTC PCB

Instructions for replacing the RTC PCB battery.

REPLACING PCBS

Procedures for replacing PCBs within the column assembly.

Chapter H CEPHALOSTAT

ADJUSTMENTS AND CALIBRATIONS

Procedures for adjusting and calibrating the cephalostat.

REMOVING AND ATTACHING THE SECOND PRIMARY COLLIMATOR

Procedures for servicing the secondary collimator.

DETACHING AND ATTACHING THE SENSOR HEAD

Procedures for detaching and attaching the sensor head.

REMOVING THE HOUSINGS AND COVERS

Procedures for removing cephalostat housings and covers.

REPLACING PCBS

Procedures for replacing PCBs in the cephalostat.

Chapter I DIAGRAMS

WIRING DIAGRAM

Electrical wiring diagrams for unit components.

Planmeca ProMax X-ray Specifications

General IconGeneral
BrandPlanmeca
ModelProMax X-ray
CategoryMedical Equipment
LanguageEnglish

Related product manuals