This command is a channel integer command. See Section 6.3 and Section 6.2 for more information
on this type of command. The minimum and maximum values for this command are 0 and 100,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
Q01AMGATER112
Set gate ratio for automatic
gating threshold to 12 dB for
input channel 1.
Q01AMGATER112
Q01AMGATER1>3
Increase gate ratio for automatic
gating threshold by 3 dB for
input channel 1.
Q01AMGATER1x, where x is between 0 and
100 depending on the current setting of the
gate ratio for input channel 1. If this command
is issued after the example above, then the
status message will be Q01AMGATER115.
Q01AMGATER1?
Query gate ratio for automatic
gating threshold for input
channel 1.
Q01AMGATER1x, where x is between 0 and
100 depending on the current setting of the
gate ratio for input channel 1. If this command
is issued after the example above, then the
status message will be Q01AMGATER115.
8.16. AMGATET -- Set Automixer Gate Threshold
This command sets the automixer gate threshold (in dB) for the specified input channel. The gate
threshold is the level that the input signal must reach in order to gate the microphone on. This value
us only used if the input is set to manual gating via the
AMAUTO command.
This command is a channel integer command. See
Section 6.3 and Section 6.2 for more information
on this type of command. The minimum and maximum values for this command are 0 and 100,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
Q01AMGATET112
Set gate threshold for manual
gating threshold to 12 dB for
input channel 1.
Q01AMGATET112

Table of Contents

Other manuals for Polycom Vortex EF2210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2210 and is the answer not in the manual?

Polycom Vortex EF2210 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2210
CategoryTelephone Accessories
LanguageEnglish

Related product manuals