Filter Type Value of Type Parameter
Parametric 1
Low Shelf 2
High Shelf 3
Lowpass 4
Highpass 5
Linkwitz-Riley Lowpass 6
Linkwitz-Riley Highpass 7
This command has the same format and restrictions as the
PEQIA command except that only one
parameter, the filter type, is specified instead of all the parameters. See the
PEQIA command for
more information. To set the slope parameter for an output parametric EQ filter, use the
PEQOT
command. To set all the parameters for an output parametric EQ filter, use the
PEQOA command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
Q01PEQIT1,2,1
Set the type of the parametric EQ
on input 1 , band 2 to parametric.
Q01PEQIT1,2,1
Q01PEQITB,1,?
Query current type setting of
parametric EQ on input B , band
1.
Q01PEQITB,1,t , where t is the current
setting of the type parameter for the
parametric EQ on input B , band 1. If the type
parameter of this filter is set to the same
value given in the example above, then the
status message will be Q01PEQITB,1,1 .
8.89. PEQOA -- Set All Parameters for Specified Parametric
EQ Output Stage
This command sets or queries all of the parameters for the parametric equalizer (EQ) filters on output
channels 1, A, and B . Each channel has five bands of parametric EQ that can be independently
controlled.
The output parametric EQ filter parameters can be set individually via the
PEQOT, PEQOF, PEQOB,
PEQOG, PEQOS, and PEQOE commands. The input parametric EQ filter parameters can be set
simultaneously via the
PEQIA command or individually with the PEQIT, PEQIF, PEQIB, PEQIG,
PEQIS, and PEQIE commands.
When using this command, you must specify all of the following parameters.

Table of Contents

Other manuals for Polycom Vortex EF2210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2210 and is the answer not in the manual?

Polycom Vortex EF2210 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2210
CategoryTelephone Accessories
LanguageEnglish

Related product manuals