command. To set all the parameters for an input parametric EQ filter, use the PEQIA command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
Q01PEQOB1,2,40
Set bandwidth of parametric EQ
on output 1 , band 2 to 40
1/100th octaves.
Q01PEQOB1,2,40
Q01PEQOBB,1,?
Query current bandwidth setting
of parametric EQ on output B ,
band 1.
Q01PEQOBB,1,b , where b is the current
setting of the bandwidth parameter for the
parametric EQ on output B , band 1. If the
bandwidth parameter of this filter is set to the
same value given in the example above, then
the status message will be Q01PEQOBB,1,40
.
8.91. PEQOE -- Set Enabled Parameter for Specified
Parametric EQ Output Stage
This command sets or queries the enabled parameter (0 = filter is disabled, 1 = filter is enabled) for
the parametric equalizer (EQ) filters on output channels 1, A, and B . Each channel has five bands of
parametric EQ that can be independently controlled.
This command has the same format and restrictions as the
PEQOA command except that only one
parameter, the enabled status, is specified instead of all the parameters. See the
PEQOA command for
more information. To set the enabled parameter for an input parametric EQ filter, use the
PEQIE
command. To set all the parameters for an intput parametric EQ filter, use the
PEQIA command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
Q01PEQOE1,2,1
Enable parametric EQ on output 1
, band 2.
Q01PEQOE1,2,1
Q01PEQOEB,1,?
Query enabled status of
parametric EQ on output B , band
1.
Q01PEQOEB,1,e , where e is the current
setting of the enabled parameter for the
parametric EQ on output B , band 1. If the
enabled parameter of this filter is set to the
same value given in the example above, then
the status message will be Q01PEQOEB,1,1 .

Table of Contents

Other manuals for Polycom Vortex EF2210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2210 and is the answer not in the manual?

Polycom Vortex EF2210 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2210
CategoryTelephone Accessories
LanguageEnglish

Related product manuals