Q01MINI2
Toggle enabled state of modem initialization 
string.
Q01MINIx , where x is 0 or 1 depending 
on the current enabled state of the 
modem initialization string. 
Q01MINI?
Query enabled state of modem initialization 
string.
Q01MINIx , where x is 0 or 1 depending 
on the current enabled state of the 
modem initialization string. 
8.72. MINISTR -- Set Modem Initialization String
This command is used to set or query the modem initialization string. The string can be a maximum 
of 32 characters long. The recommended modem initialization string for the Vortex is: 
ATF1E0&B1S0=2 
This can be set via the following command. 
Q01MINISTRATF1E0&B1S0=2 
Whether or not the modem initialization string is sent at power-up is controlled via the 
MINI 
command. 
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved 
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned. 
Example Description Status Message
Q01MINISTRATF1E0&B1S0=2
Set modem initialization 
string to 
ATF1E0&B1S0=2. 
Q01MINISTRATF1E0&B1S0=2
Q01MINISTR?
Query current modem 
initialization string. 
Q01MINISTR<string> , where 
<string> is the current modem 
initialization string. If this command was 
sent after the above example, then the 
status message would be 
Q01MINISTRATF1E0&B1S0=2 . 
8.73. MMUTE -- Mute Crosspoint in Main Matrix or 
Submatrix
This command sets or queries the mute status of one or more crosspoints in either the main matrix or 
one of the EF Bus submatrices. 
This command is a matrix boolean command. See 
Section 6.4 and Section 6.1 for more information 
on this type of command.