EasyManuals Logo

Polycom Vortex EF2210 User Manual

Polycom Vortex EF2210
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Q01AMNOMAT11
Enable NOM attenuation on
output 1 .
Q01AMNOMAT11
Q01AMNOMATA0
Disable NOM attenuation on
output A.
Q01AMNOMATA0
Q01AMNOMATB2
Toggle NOM attenuation status
on output B.
Q01AMNOMATBx , where x is either 0 or 1
depending on the current mute status of NOM
attenuation on the ouptut.
Q01AMNOMATB?
Query NOM attenuation status
of output B.
Q01AMNOMATBx , where x is either 0 or 1
depending on the current NOM attenuation
status of the output.
Q01AMNOMAT*1
Enable NOM attenuation on all
outputs (1, A, B) .
Q01AMNOMAT*111
Q01AMNOMAT*0
Disable NOM attenuation on all
outputs (1, A, B) .
Q01AMNOMAT*000
Q01AMNOMAT*100
Enable NOM attenuation on
output 1, and disable NOM
attenuation on outputs A and B.
Q01AMNOMAT*100
Q01AMNOMAT*2
Toggle status of NOM
attenuation on all outputs.
Q01AMNOMAT*abc , where each of the letters
(a, b, etc.) is either 0 or 1 depending of the
current status of NOM attenuation on the
corresponding output. If this command was
sent after the example above, then the status
message would be Q01AMNOMAT*011 .
Q01AMNOMAT*?
Query NOM attenuation status
of all outputs.
Q01AMNOMAT*abc , where each of the letters
(a, b, etc.) is either 0 or 1 depending of the
current status of the NOM attenuation on the
corresponding output. If this command was
sent after the example above, then the status
message would be Q01AMNOMAT*011 .
8.23. AMOFFAT -- Set Off Attenuation for the Specified
Automixer
This command sets the off attenuation (in dB) for the specified automixer. Setting this value to 18
would result in the microphone signals being attenuated by 18 dB when gated off. This value is set
independently for each of the automixers. The first argument of this command specifies the
automixer number (1-2) to adjust. The second argument specifies the off attenuation.
Even though this is a channel integer command, use of the wildcard for specifying the automixer
number is not supported.
This command is a channel integer command. See
Section 6.3 and Section 6.2 for more information
on this type of command. The minimum and maximum values for this command are 1 and 100,
respectively.

Table of Contents

Other manuals for Polycom Vortex EF2210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2210 and is the answer not in the manual?

Polycom Vortex EF2210 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2210
CategoryTelephone Accessories
LanguageEnglish

Related product manuals