This command is an integer command. See Section 6.2 for more information on this type of 
command. The minimum and maximum values for this command are 0 and 5000, respectively. 
This command is saved to non-volatile memory only as part of a preset. The state of this command 
will be restored after power-up only if a preset is saved and that preset is set to be the power-on 
preset. 
Example Description Status Message
Q01AMHOLD500
Set automixer hold time to 500 
ms. 
Q01AMHOLD500
Q01AMHOLD>500
Increase automixer hold time by 
500 ms. 
Q01AMHOLDx, where x is between 0 and 
5000 depending on the current AMHOLD 
setting. If this command is issued after the 
above example, then the status message will 
be Q01AMHOLD1000
Q01AMHOLD?
Query automixer hold time. 
Q01AMHOLDx, where x is between 0 and 
5000 depending on the current AMHOLD 
setting. If this command is issued after the 
above example, then the status message will 
be Q01AMHOLD1000
8.19. AMLMM -- Set Last Mic On Mode for Specified 
Automixer
This command sets "last mic on" mode for the specified automixer. The first argument specifies which 
automixer (always 1 on the EF2210) The second parameter specifies the operation of "last mic on" 
mode and can be one of the following: 
● 0 - last mic mode is off
● 1 - manual (use a specific mic)
● 2 - automatic (the last gated mic remains on)
Even though this is a channel integer command, use of the wildcard character for specifying the 
automixer number is not supported. 
This command is a channel integer command. See 
Section 6.3 and Section 6.2 for more information 
on this type of command. The minimum and maximum values for this command are 0 and 2, 
respectively. 
This command is saved to non-volatile memory only as part of a preset. The state of this command 
will be restored after power-up only if a preset is saved and that preset is set to be the power-on 
preset. 
Example Description Status Message