This command is an integer command. See Section 6.2 for more information on this type of
command. The minimum and maximum values for this command are 0 and 5000, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
Q01AMHOLD500
Set automixer hold time to 500
ms.
Q01AMHOLD500
Q01AMHOLD>500
Increase automixer hold time by
500 ms.
Q01AMHOLDx, where x is between 0 and
5000 depending on the current AMHOLD
setting. If this command is issued after the
above example, then the status message will
be Q01AMHOLD1000
Q01AMHOLD?
Query automixer hold time.
Q01AMHOLDx, where x is between 0 and
5000 depending on the current AMHOLD
setting. If this command is issued after the
above example, then the status message will
be Q01AMHOLD1000
8.19. AMLMM -- Set Last Mic On Mode for Specified
Automixer
This command sets "last mic on" mode for the specified automixer. The first argument specifies which
automixer (always 1 on the EF2210) The second parameter specifies the operation of "last mic on"
mode and can be one of the following:
0 - last mic mode is off
1 - manual (use a specific mic)
2 - automatic (the last gated mic remains on)
Even though this is a channel integer command, use of the wildcard character for specifying the
automixer number is not supported.
This command is a channel integer command. See
Section 6.3 and Section 6.2 for more information
on this type of command. The minimum and maximum values for this command are 0 and 2,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message

Table of Contents

Other manuals for Polycom Vortex EF2210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2210 and is the answer not in the manual?

Polycom Vortex EF2210 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2210
CategoryTelephone Accessories
LanguageEnglish

Related product manuals