8.92. PEQOF -- Set Frequency Parameter for Specified
Parametric EQ Output Stage
This command sets or queries the frequency parameter (in Hz) for the parametric equalizer (EQ)
filters on output channels 1, A, and B . Each channel has five bands of parametric EQ that can be
independently controlled.
The minimum and maximum values for the frequency parameter are 20 and 20000, respectively.
For filter types that have a center frequency (e.g., parametric), this parameter specifies the center
frequency. For filter types that have a cutoff frequency (e.g, highpass, lowpass, etc.), this parameter
specifies the cutoff frequency.
This command has the same format and restrictions as the
PEQOA command except that only one
parameter, the frequency, is specified instead of all the parameters. See the
PEQOA command for
more information. To set the frequency parameter for an input parametric EQ filter, use the
PEQIF
command. To set all the parameters for an input parametric EQ filter, use the
PEQIA command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
Q01PEQOF1,2,1250
Set frequency of parametric
EQ on output 1 , band 2 to
1250 Hz.
Q01PEQOF1,2,1250
Q01PEQOFB,1,?
Query current frequency
setting of parametric EQ on
output B , band 1.
Q01PEQOFB,1,f , where f is the current
setting of the frequency parameter for the
parametric EQ on output B , band 1. If the
frequency parameter of this filter is set to the
same value given in the example above, then
the status message will be
Q01PEQOFB,1,1250 .
8.93. PEQOG -- Set Gain Parameter for Specified Parametric
EQ Output Stage
This command sets or queries the gain parameter (in dB) for the parametric equalizer (EQ) filters on
output channels 1, A, and B . Each channel has five bands of parametric EQ that can be
independently controlled.
The minimum and maximum values for the gain parameter are -20 and 20, respectively.
This command has the same format and restrictions as the
PEQOA command except that only one

Table of Contents

Other manuals for Polycom Vortex EF2210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2210 and is the answer not in the manual?

Polycom Vortex EF2210 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2210
CategoryTelephone Accessories
LanguageEnglish

Related product manuals