Q01AMGATET1>3
Increase gate threshold for 
manual gating threshold by 3 dB 
for input channel 1. 
Q01AMGATET1x, where x is between 0 and 
100 depending on the current setting of the 
gate threshold for input channel 1. If this 
command is issued after the example above, 
then the status message will be 
Q01AMGATET315. 
Q01AMGATET1?
Query gate threshold for manual 
gating threshold for input 
channel 1. 
Q01AMGATET1x, where x is between 0 and 
100 depending on the current setting of the 
gate threshold for input channel 1. If this 
command is issued after the example above, 
then the status message will be 
Q01AMGATET115. 
8.17. AMGNOM -- Set Global Maximum Number of Open 
Mics for Bus Automixer
This command sets the global maximum number of open mics (NOM) allowed for the specified bus 
automixer. The NOM limit is a global limit, meaning that this applies to all bus automixers with the 
same 
AMBUSID. In contrast, the AMNOM command is a local limit that applies to the local automixer in 
the EF2210. 
The first argument of this command specifies the automixer number (always 1 in the EF2210) to 
adjust. The second argument specifies the NOM limit (1-64). Even though this is a channel integer 
command, use of the wildcard for specifying the automixer number is not supported. 
This command is a channel integer command. See 
Section 6.3 and Section 6.2 for more information 
on this type of command. The minimum and maximum values for this command are 1 and 64, 
respectively. 
This command is saved to non-volatile memory only as part of a preset. The state of this command 
will be restored after power-up only if a preset is saved and that preset is set to be the power-on 
preset. 
Example Description Status Message
Q01AMGNOM13
Set global NOM for the automixer to a 
maximum of 3 mics. 
Q01AMGNOM13
Q01AMGNOM1?
Query current global NOM limit for 
the automixer. 
Q01AMGNOM1x, where x is between 1 and 
64 depending on the current setting of the 
global NOM limit for the automixer. 
8.18. AMHOLD -- Set Automixer Hold Time