DESCRIPTION OF PROGRAMMING PARAMETERS
Note: Comes from the previous page.
In IP66 equipment, pulse
input TI and Multi-function
terminal P5 share the
same terminal. In this
case, set parameter In.69
to 54(TI).
Digital input
activation
delay
Set the delay time when activating the digital
input. In case any variation occurs within a
smaller time gap, the input will remain
disabled.
Digital input
deactivation
delay
Set the delay time when disabling a digital
input. In case any variations occur within a
smaller time gap, the input will remain
enabled.
Digital input
contact type
Adjust each to 0 or 1 according to the following
table:
Contact normally open (YES)
Contact normally closed (NC)
The assignment order is P1, P2, …, P7
starting from the bit placed farthest to the right.
The number of Digital Inputs varies depending
on the equipment (IP20 drives integrate 7
Digital Inputs and IP66 drives integrate 5).
Set the time to wait before refreshing the
digital inputs configured as multireference.