PowerFleet
®
VAC4 and VAC4S Hardware User’s Guide
085-00000700 Rev K
support@powerfleet.com
Page 81 of 103
30- FWD Motion Error (Refer to Hardware Guide)
[SHUTDOWN] VAC does not sense consistent forward motion.
Possible Cause(s)
Action
Speeding during drive
forward test
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
Drive slowly where directed.
Insufficient “BLU”
(motion sensing)
connection point
Verify that the “BLU” wire is connected to the proper traction (motion) sensing circuit. Refer to
the PowerFleet
®
Installation Guide.
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Failed fuse on “BLU”
(motion sensing) wire
Verify that the fuse for the “BLU” wire is not blown or missing.
Repair as needed.
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Incorrect forward motion
values
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
Log in to the VAC and review the motion values (see: “Defining ‘Motion’ Manually”).
Adjust values as needed.
Vehicle cable
Use an ohmmeter to check resistance to verify cable integrity (an “open” or zero reading
indicates a damaged cable) on the “BLU” wire.
Replace the cable as needed and retest.
31-RVS Motion Error (Refer to Hardware Guide)
[SHUTDOWN] VAC does not sense consistent reverse motion.
Possible Cause(s)
Action
Speeding during drive
forward test
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
Drive slowly where directed.
Insufficient “BLU”
(motion sensing)
connection point
Verify that the “BLU” wire is connected to the proper traction (motion) sensing circuit. Refer to
the PowerFleet
®
Installation Guide.
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Failed fuse on “BLU”
(motion sensing) wire
Verify that the fuse for the “BLU” wire is not blown or missing.
Repair as needed.
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Incorrect reverse motion
values
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
Log in to the VAC and review the motion values (see: “Defining ‘Motion’ Manually”).
Adjust values as needed.