38-Access Relay Err (Refer to Hardware Guide)
[SHUTDOWN] During the “disable access control” test, the VAC did not disable the engine as designed.
Possible Cause(s)
Action
”2” and “4” wire
connection points (and
“6” and “8” for internal
combustion vehicles)
Verify that the”2” and “4” connection points (and “6” and “8” for internal combustion
vehicles) are connected to a circuit that will inhibit the vehicle from moving (or shut
the vehicle down for internal combustion vehicles) when you are not logged into the
VAC. See the PowerFleet
®
Installation Guide for recommended connection points.
39-Forkload Config Er See Hardware Guide
[FUNCTIONAL] The forkload sensor has not been calibrated successfully.
Possible Cause(s)
Action
Forkload sensor not
calibrated
Log in to the VAC as a Maintenance operator and re-run the Sensors wizard from the
Install menu
Follow the load configuration instructions.
40-Forkload Config Er See Hardware Guide
[FUNCTIONAL] The forkload sensor has not been calibrated successfully.
Possible Cause(s)
Action
Forkload sensor has a
bad installation or
calibration
Check the load sensor installation and wiring to the sensor hub
Log in to the VAC as a Maintenance operator and re-run the Sensors wizard from the
Install menu
Follow the load configuration instructions.