PowerFleet
®
VAC4 and VAC4S Hardware User’s Guide
085-00000700 Rev K
support@powerfleet.com
Page 88 of 103
45-Serial Data Error (Refer to Hardware Guide)
[FUNCTIONAL] The serial data communication (OEM CAN, etc.) has too many invalid packets.
Possible Cause(s)
Action
Serial/CAN cable connection
compromised
Verify that the Serial/CAN cable is properly connected to both the Serial/CAN connection in
the vehicle and the C102 connection on the VAC
Verify that the Serial/CAN cable is not damaged
Serial/CAN not
communicating from vehicle
See vehicle manufacturer’s troubleshooting guide.
46-VAC Button Error (Refer to Hardware Guide)
[FUNCTIONAL] One of the VAC keypad buttons is stuck in the ‘pressed’ position.
Possible Cause(s)
Action
Keypad malfunction
Complete an RMA Request form (See Appendix A)
Call PowerFleet’s Customer Service for an RMA number.
Only the VAC should be returned for analysis/repair.
Once VAC is removed, system MUST be hard-bypassed to use vehicle.
Follow instructions on how to hard-bypass the system. (See Appendix B)
Run “CloneVAC” on the new VAC (see Section 4 for instructions)
47-Facility Code Error (Refer to Hardware Guide)
[FUNCTIONAL] The facility ID entered in the VAC does not match the facility ID being transmitted by the currently in-
range system.
Possible Cause(s)
Action
Incorrect facility ID
Update the VAC’s facility ID
o Log into the VAC as a Maintenance operator
o Navigate to the Access > FacilityID screen
o Enter the facility ID provided by PowerFleet Support
Multiple facilities have
overlapping wireless
coverage
Could also be an Incorrect Server IP or Port; Verify this also
Contact PowerFleet Support
48-Wi-Fi FC IP Port Err (Refer to Hardware Guide)
[FUNCTIONAL] The facility ID is zero or the facility ID entered in the VAC does not match the facility ID being
transmitted by the currently in-range system.
Possible Cause(s)
Action
Incorrect facility ID
Update the VAC’s facility ID
o Log into the VAC as a Maintenance operator
o Navigate to the Access > FacilityID screen
o Enter the facility ID provided by PowerFleet Support
Could also be an Incorrect Server IP or Port; Verify this also.
Multiple facilities have
overlapping wireless
coverage
Contact PowerFleet Support