EasyManuals Logo

PROLEC James Fisher PME400 User Manual

PROLEC James Fisher PME400
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
562400-000, Issue 1.3 January 2022
Page 19 of 61
7.1.3. Height Limit Setting - Using Current Highest Point
Set the limit using the current highest point of the machine.
Ensure the tool is off the ground before setting the limit.
Step One: Move the equipment to the required height limit and press the ‘Set using highest point of
equipment’ button
Step Two: Check the limit and press Green TICK to accept.
If you attempt to set a height limit below the current machine height, an
error will be shown. Move the machine to be lower than the desired
height, and then try again.
Once a limit is set, the internal alarm will sound and the RED LED will
light if the equipment exceeds the current limit. Always check that the
current limit activates at the set point. The restriction cannot be
deactivated if in the alarm state. Observe the operational limitations
given in section
4
.
Move equipment to
required height limit
and press this button
Height limit shown
here
Exit without
change
Accept the value
shown