EasyManuals Logo

Pulsar SLUDGE FINDER 2 User Manual

Pulsar SLUDGE FINDER 2
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
Page 95
P210, P220, P230, P240, P250, P260 - Relay Type
This parameter defines what type each relay should be, see the table below for
available options.
Option
Description
0= Not In Use (Default)
Relay not in use or programmed and LED will
always be off.
1= Alarm
Relay is programmed as an alarm relay, which
will de-energise ON, and energise OFF.
This will ensure an alarm is raised if the
power fails to the unit.
2= Control
Relay is programmed as a control relay,
which will energise ON, and de-energise
OFF.
3= Miscellaneous
Relay is programmed as a miscellaneous
relay, which will energise ON, and de-
energise OFF.