Page 118
Daylight Saving Time
Important Information
In order to ensure the correct operation of Daylight Saving Time P932 Time
should be checked, and adjusted if necessary, to ensure that it is set for the
current valid time.
P970 DST Enable
When Enabled (set to 1) the internal clock will be automatically adjusted to
compensate for the difference between standard time and Daylight Saving Time.
Default = 1 (Yes)
P971 DST Difference
This parameter sets the time difference between standard time and Daylight
Saving Time. The time difference is entered in HH:MM. Default = 01:00
P972 DST Start Time
This parameter is used to set the time of day at which Daylight Saving Time will
start, the time is entered in the format HH: MM (24-hour format). Default = 02:00
P973 Start Day
Use this parameter to enter the day of the week (P974) that Daylight Saving Time
is to start.
Option
Description
2= Monday
DST will start on a Monday
3= Tuesday
DST will start on a Tuesday
4= Wednesday
DST will start on a Wednesday
5= Thursday
DST will start on a Thursday
6= Friday
DST will start on a Friday
7= Saturday
DST will start on a Saturday
8= Sunday (Default)
DST will start on a Sunday

Table of Contents

Other manuals for Pulsar SLUDGE FINDER 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pulsar SLUDGE FINDER 2 and is the answer not in the manual?

Pulsar SLUDGE FINDER 2 Specifications

General IconGeneral
BrandPulsar
ModelSLUDGE FINDER 2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals