Page 48
Inputs. Discrete I/P OFF condition, PNP Less than 5V, NPN Greater than 2V or
Open. Analogue I/P Rating 24ma, Impedance 100 ohms, Sample Rate 1 second or 1%,
Resolution 12bit
Outputs. OFF State Leakage Less than 10 micro amps, Max End to End Latency 300
milliseconds. Analogue Outputs. Update Rate 125ms Accuracy 0.1%, Resoluton 12bit
Environmental. Rating IEC IP67, NEMA 6. Operating temp -40 to 85 deg C.
Operating Humidity 95%. Radiated Immunity 10v/m, 80-2700MHz (EN61000-6-2)
Shock and Vibration. IEC 68-2-6 and IEC68-2-7, Shock 30g 11ms half sine wave,
18 shocks, Vibration 0.5mm p-p 10 to 60 Hz.