Specifications (continued)
Optional Interfaces: IEEE-488
Enhanced Remote:
Inputs: Start, Stop, Test Selection
Characteristics: TTL active low, Pulse width >1ms
Outputs: Under Test, Pass, Fail, Fail Hi, Fail Lo, Fail Arc, Fail Cont
Characteristics: Dry contact relay, Closed if true
36V, 100mA max
Connector: 25 pin male D-series (compatible w/Sentry Series via a adaptor)
Mechanical: Bench Mount (optional rack mount flanges available, 2000-16)
Dimensions:(w x h x d): 17x5.25x16in (432x133x406mm)
Weight: 29 lbs (13kg) net, 36 lbs (16kg) shipping
Environmental: Meets MIL-T-28800E, Type 3, Class 5
Operating: 0 to 40
o
C
Storage: -10 to 60
o
C
Humidity: Maximum RH of 80% for temperatures up to 31
o
C
and decreasing linearly to 50% at 40
o
C
Warm-up Time: 1 minute
Indoor Use: Altitude up to 2000m
Pollution Degree 1, Installation Category II
Power: • 100 - 240V AC +/-10% • 50 – 60 Hz • 300W max
Supplied: • Instruction Manual • Power Cable
• Calibration Certificate • Test Leads (3)
Ordering Description Catalog No.
Information: AC Hipot Tester Guardian 2510
AC/DC Hipot Tester Guardian 2520
AC/DC/IR Hipot Tester Guardian 2530