EB200 Manual FORMat subsystem
4052.2000.02 4.35 E-7
. :MEMory ASCii|PACKed
Specifies the output format of the queries MEMory:CONTents?
Parameters:
ASCii output in ASCII format
PACKed output in internal binary data format
*RST state:
ASCii
Example:
FORMat:MEMory PACKed
. :MEMory?
Query of output format of above-mentioned queries
Parameters:
none
Result:
ASC, PACK
Example:
FORMat:MEMory? -> PACK
. :SREGister ASCII|BINary|HEXadecimal
Specifies with which data format the queries of all CONDition, EVENt, ENABle, PTRansition,
NTRansition registers and all IEEE-488.2 status registers are to be carried out.
Parameters:
ASCii output as decimal figure in ASCII code (eg 128)
BINary output as binary figure in ASCII code (eg #B1000000000000000)
HEXadecimal output as hexadecimal figure in ASCII code (eg #H8000)
*RST state:
ASCii
Example:
FORMat:SREGister HEXadecimal