EB200 Manual OUTPut subsystem
4052.2000.02 4.53 E-7
. . . :THReshold? [MINimum|MAXimum]
Query of level tone reference threshold
Parameters:
none query of current level tone reference threshold
MINimum|MAXimum query of lowest/highest level tone reference threshold
Result:
Level tone reference threshold in dBuV
Example:
OUTPut:TONE:THReshold? MIN -> 6
. . . . :STEP
. . . . . [:INCRement] <numeric_value>|MINimum|MAXimum
Setting the stepwidth for the OUTP:TONE:THR UP|DOWN command
Parameters:
<numeric_value> stepwidth for level tone reference threshold in dBuV
MINimum|MAXimum setting the smallest/largest stepwidth
*RST state:
1 dBuV
Example:
OUTP:TONE:THR:STEP 10 dB
µV
. . . . . [:INCRement]? [MINimum|MAXimum]
Query of stepwidth
Parameters:
none query of currently set stepwidth
MINimum|MAXimum query of smallest/largest stepwidth
Result:
Stepwidth for level tone reference threshold in dBuV
Example:
OUTP:TONE:THR:STEP? -> 10