Minimum factor
The machine control unit automatically sets the minimum factor to one of the following values,
depending on the entered value:
The minimum factor is 0.2 if the entered value is less than 0.5
The minimum factor is 0.4 if you enter a value over 0.5.
4.4.4 Drop point
With the AXIS EMC mineral fertilizer spreader, the drop point is set via the electrical drop point
adjustment exclusively.
u
Access the menu Fertiliser settings > Drop point.
u
Determine the position for the drop point using the fertilizer chart.
u
Enter the determined value in the input field.
u
Press OK.
The Fertiliser settings window appears with the new drop point.
If the drop point is blocked, alarm 17 is displayed; refer to chapter 6 Alarm messages and possible
causes.
CAUTION!
Risk of injury due to automatic adjustment of the drop point
When the Start/Stop function key is pressed, the drop point is automatically moved to the preset
value by an electrical actuator (Speedservo). This may cause injury.
Before pressing the Start/Stop key, ensure that nobody is present in the hazard zone of the
machine.
Acknowledge the “Approach drop point” alarm message by pressing Start/Stop.
4.4.5 Calibration
The Start calibration menu is locked for weighing spreaders and all machines in the
operating mode AUTO km/h + AUTO kg. This menu item is inactive.
In this menu, the flow factor can be determined based on a calibration and saved in the machine
control unit.
Execute the calibration:
Before spreading for the first time
If the fertilizer quality has changed significantly (moisture, high dust content, granulate damage)
If a new fertilizer type is used
4. Operation
AXIS EMC ISOBUS 5902180-h-gb-
37