We recommend displaying the flow factor in the working screen (refer to 2.2.2 Display fields), in
order to monitor the mass flow control while spreading.
In case of any problems with flow factor control (clogging, ...), after troubleshooting at a standstill,
switch to the Fertilizer settings menu and enter the flow factor 1.0.
Resetting the flow factor
If the flow factor has fallen below the minimum value (0.4 and/or 0.2), alarm no. 47 and/or 48 appears.
See 6.1 Meaning of the alarm messages.
5.7 Idle measurement
5.7.1 Automatic idle measurement
In order to achieve a high control accuracy, the EMC control must regularly measure and store the
idling pressure.
The idle measurement for the determination of the idling pressure will start when the system is
restarted.
It will also automatically start the idle measurement under the following conditions:
• The defined period since the last idle measurement has expired.
• You have made changes in the Fertilizer settings menu (RPM, type of spreading disc).
During the idle measurement, the following window appears.
5. Spreading operation
84
5902180-h-gb- AXIS EMC ISOBUS