6 Alarm messages and possible causes
6.1 Meaning of the alarm messages
Various alarm messages can be displayed on the ISOBUS terminal display.
No. Message in display Meaning and possible cause
1 Fault in dosing system,stop ! The motor of the metering system cannot reach
the specified target value:
Blockage
No position feedback
2 Max. outlet reached!Speed or application
ratetoo high
Metering slider alarm
The maximum metering opening is
reached.
The set application rate (+/- quantity)
exceeds the maximum metering opening.
3 Flow factor is outsidelimits The flow factor must lie within a range between
0.40 and 1.90.
The newly calculated or entered flow
factor is outside this range
4 Hopper left empty! The filling level sensor on the left reports
“empty.”
The left hopper is empty.
5 Hopper right empty! The filling level sensor on the right reports
“empty.”
The right hopper is empty.
14 Error by setting TELIMAT Alarm for the TELIMAT sensor
This error message is displayed if the TELIMAT
status is not detected for more than 5 seconds.
15 Memory full,Delete oneprivate fertiliser chart A maximum of 30 fertilizer types are stored in
the memory for the fertilizer charts.
16 Approach drop pointYes = Start Safety request before the drop point is
automatically approached
Drop point setting in the menu Fertiliser
settings
Fast emptying
6. Alarm messages and possible causes