Tare the scales before each use in order to ensure problem-free calculation of the remaining
quantity.
4.10 Operating lights (SpreadLight)
In this menu, you can activate the SpreadLight function, to monitor the spreading pattern even in night
mode.
You can switch the operating lights on and off in the automatic and/or manual mode via the machine
control unit.
Fig. 29: Menu SpreadLight
[1] Turn off delay (s)
[2] Manual mode: Switch on operating lights
[3] Activate automatic mode
Automatic mode:
In the automatic mode, the operating lights are switched on as soon as the metering sliders open and
the spreading process starts.
u
Access the menu Main menu > SpreadLight.
u
Put a check mark in the menu item SpreadLight AUTO [3].
The operating lights are switched on when the metering sliders open.
u
Enter a turn off duration [1] in seconds.
The operating lights will switch off at the end of the entered time, if the metering sliders are
closed.
Range from 0 to 100 seconds.
u
Remove the check mark in the menu item SpreadLight AUTO [3].
The automatic mode is deactivated.
4. Operation
64
5902180-h-gb- AXIS EMC ISOBUS